[BS] 1404.16.1 Panel Siding
JUMP TO FULL CODE CHAPTER
Fiber-cement panels shall comply with the requirements of ASTM C1186, Type A, minimum Grade II (or ISO 8336, Category A, minimum Class 2). Panels shall be installed with the long dimension either parallel or perpendicular to framing. Vertical and horizontal joints shall occur over framing members and shall be protected with caulking, with battens or flashing, or be vertical or horizontal shiplap or otherwise designed to comply with Section 1402.2. Panel siding shall be installed with fasteners in accordance with the approved manufacturer's instructions.
Related Code Sections
1404.16.1 Exterior Walls, Panel Siding
1402.2. Panel siding shall be installed with fasteners in accordance with the approved manufacturer's instructions ...
Building Code 2021 of Illinois > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.16 Fiber-Cement Siding > 1404.16.1 Panel Siding
1404.16.1 Exterior Walls, Panel Siding
1402.2. Panel siding shall be installed with fasteners in accordance with the approved manufacturer's instructions ...
Building Code 2018 of Illinois > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.16 Fiber-Cement Siding > 1404.16.1 Panel Siding
3115.8.4.3 Special Construction, Allowable Shear Value
The allowable shear values for the intermodal shipping container corrugated steel sheet panel side walls and end walls shall be demonstrated ...
Building Code 2021 of Illinois > 31 Special Construction > 3115 Intermodal Shipping Containers > 3115.8 Structural > 3115.8.4 Detailed Design Procedure > 3115.8.4.3 Allowable Shear Value
2308.6.3 Wood, Braced Wall Panel Methods
" long, 16 gage staples
6" o.c. on all framing members
HPS Hardboard panel siding
7 / 16 " in accordance with Table 2308.6.3(5 ...
Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.6 Wall Bracing > 2308.6.3 Braced Wall Panel Methods
2308.6.3 Wood, Braced Wall Panel Methods
, 16 gage staples
6" o.c. on all framing members
HPS Hardboard panel siding
7 / 16 " in accordance with Table 2308.6.3(5)
Table ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.6 Wall Bracing > 2308.6.3 Braced Wall Panel Methods