• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

909.16.2 Panel Controls

NYC Building Code 2022 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Firefighter's Smoke Control Panel > 909.16.2 Panel Controls
JUMP TO FULL CODE CHAPTER
The firefighter's control panel shall provide control capability over the complete smoke control system equipment within the building as follows:
  1. ON-AUTO-OFF control over each individual piece of operating smoke control equipment that can also be controlled from other sources within the building. This includes stairway pressurization fans; smoke exhaust fans; supply, return and exhaust fans; elevator shaft fans and other operating equipment used or intended for smoke control purposes.
  2. OPEN-AUTO-CLOSE control over dampers relating to smoke control and that are also controlled from other sources within the building. Dampers are permitted to be controlled by individual damper or grouped by smoke zone.
  3. ON-OFF or OPEN-CLOSE control over smoke control and other critical equipment associated with a fire or smoke emergency and that can only be controlled from the firefighter's control panel. The firefighter's control panel shall be configured as described in Section 911.
Exceptions:
  1. Systems, where approved by the commissioner and the Fire Department, where the controls and indicators are combined to control and indicate all elements of a single smoke zone as a unit.
  2. Systems, where approved by the commissioner and the Fire Department, where the control is accomplished by computer interface using approved, plain English commands.

Related Code Sections


909.16.2 Fire Protection Systems, Panel Controls
The fire fighter's control panel shall provide control capability over the complete smoke-control system equipment within the building as follows ...
NYC Building Code 2014 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Fire-Fighter's Smoke Control Panel > 909.16.2 Panel Controls
909.16.2 Fire Protection Systems, Panel Controls
The firefighter's control panel shall provide control capability over the complete smoke control system equipment within the building as follows ...
NYC Building Code 2022 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Firefighter's Smoke Control Panel > 909.16.2 Panel Controls
909.16.2 Fire Protection Systems, Panel Controls
The fire fighter's control panel shall provide control capability over the complete smoke-control system equipment within the building as follows ...
NYC Building Code 2008 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.16 Fire-Fighter's Smoke Control Panel > 909.16.2 Panel Controls
3006.1.2.10 Elevators and Conveying Systems, Control Panel
A fire-fighter's smoke control panel complying with Section 909.16 shall be provided ...
NYC Building Code 2022 > 30 Elevators and Conveying Systems > 3006 Elevator Lobbies and Hoistway Opening Protection > 3006.1 Elevator, Dumbwaiter and Other Hoistways > 3006.1.2 Enclosed Elevator Lobby > 3006.1.2.10 Control Panel
708.14.2.10 Fire and Smoke Protection Features, Control Panel
A control panel complying with Section 909.16 shall be provided ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 708 Shaft Enclosures > 708.14 Elevator, Dumbwaiter and Other Hoistways > 708.14.2 Enclosed Elevator Lobby > 708.14.2.10 Control Panel
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING