R703.8.1 Pan Flashing of Windows and Doors
JUMP TO FULL CODE CHAPTER
Pan flashing shall be installed in accordance with the fenestration manufacturer's installation and flashing instructions. Where flashing instructions or details are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water-resistive barrier for subsequent drainage.
Exceptions:
- Windows or doors installed in accordance with the manufacturer's installation instructions which include an alternate flashing method.
- Windows or doors in detached accessory structures.
- Skylights, bow or bay windows.
- Doors required to meet accessibility requirements that would prevent the installation of pan flashing.
- Repairs or replacement of existing windows and doors.
- When a method is provided by a registered design professional.
Related Code Sections
R703.4.1 Wall Covering, Pan Flashing of Windows and Doors
instructions or details are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed ...
2020 Minnesota Residential Code > 7 Wall Covering > R703 Exterior Covering > R703.4 Flashing > R703.4.1 Pan Flashing of Windows and Doors
R703.8.1 Wall Covering, Pan Flashing of Windows and Doors
instructions or details are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed ...
Minnesota Residential Code 2015 > 7 Wall Covering > R703 Exterior Covering > R703.8 Flashing > R703.8.1 Pan Flashing of Windows and Doors
R703.4 Wall Covering, Flashing
be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or sloped in such a manner as to direct water to the surface ...
1405.4 Exterior Walls, Flashing
be installed at the perimeters of exterior door and window assemblies, penetrations and terminations of exterior wall assemblies, exterior wall ...
Minnesota Building Code 2015 > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.4 Flashing
1404.4 Exterior Walls, Flashing
shall be installed at the perimeters of exterior door and window assemblies, penetrations and terminations of exterior wall assemblies, exterior ...
2020 Minnesota Building Code > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.4 Flashing