• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1230.2.7 Padding

California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1230 [BSCC] Minimum Standards for Juvenile Facilities > 1230.2 Design Criteria for Furnishings and Equipment > 1230.2.7 Padding
JUMP TO FULL CODE CHAPTER
In safety rooms, padding shall cover the entire floor, door, walls and everything on the walls to a clear height of 8 feet (2438 mm). Benches or platforms are not to be placed on the floor of this room.
All padded rooms must be equipped with a tamper-resistant fire sprinkler as approved by the State Fire Marshal. All padding must be:
  1. Approved for use by the State Fire Marshal;
  2. Nonporous to facilitate cleaning;
  3. At least 1/2 inch (12.7 mm) thick;
  4. Of a unitary or laminated construction to prevent its destruction by teeth, hand tearing or small metal objects;
  5. Firmly bonded to all padded surfaces to prevent tearing or ripping; and,
  6. Without any exposed seams susceptible to tearing or ripping.

Related Code Sections


1230.2.7 Interior Environment, Padding
In safety rooms, padding shall cover the entire floor, door, walls and everything on the walls to a clear height of 8 feet (2438 mm). Benches ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1230 [BSCC] Minimum Standards for Juvenile Facilities > 1230.2 Design Criteria for Furnishings and Equipment > 1230.2.7 Padding
1230.2.7 Interior Environment, Padding
In safety rooms, padding shall cover the entire floor, door, walls and everything on the walls to a clear height of 8 feet (2438 mm). Benches ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1230 [BSCC] Minimum Standards for Juvenile Facilities > 1230.2 Design Criteria for Furnishings and Equipment > 1230.2.7 Padding
1231.3.8 Interior Environment, Cell Padding
In sobering cells, the floor and partition shall be padded. In safety cells, padding must cover the entire floor, doors, and walls and everything ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1231 [BSCC] Local Detention > 1231.3 Design Criteria for Furnishings and Equipment > 1231.3.8 Cell Padding
1231.3.8 Interior Environment, Cell Padding
In sobering cells, the floor and partition shall be padded. In safety cells, padding must cover the entire floor, doors, and walls and everything ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1231 [BSCC] Local Detention > 1231.3 Design Criteria for Furnishings and Equipment > 1231.3.8 Cell Padding
1309.3.6.3 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Abrasive Pads
Clean, nonshedding, abrasive pads shall be used to clean the exterior surfaces of the tube ends. [NFPA 99:5.1.10.4.3.5] Exception: For Category ...
California Plumbing Code 2016 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.3 Brazed Joints and Fittings > 1309.3.6 Cleaning Procedures > 1309.3.6.3 Abrasive Pads
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING