• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

6.4.1.5.2 Packaged Terminal Air Conditioners

Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Illinois > 6 Heating, Ventilating, and Air Conditioning > 6.4 Mandatory Provisions > 6.4.1 Equipment Efficiencies, Verification, and Labeling Requirements > 6.4.1.5 Labeling > 6.4.1.5.2 Packaged Terminal Air Conditioners
JUMP TO FULL CODE CHAPTER
Nonstandard-size packaged terminal air conditioners and heat pumps with existing sleeves having an external wall opening of less than 16 in. high or less than 42 in. wide and having a cross-sectional area less than 670 in.2 shall be factory labeled as follows: Manufactured for nonstandard-size applications only: Not to be installed in new construction projects.

Related Code Sections


6.4.1.5.2 Heating, Ventilating, and Air Conditioning, Packaged Terminal Air Conditioners
Nonstandard-size packaged terminal air conditioners and heat pumps with existing sleeves having an external wall opening of less than 16 in. high ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Illinois > 6 Heating, Ventilating, and Air Conditioning > 6.4 Mandatory Provisions > 6.4.1 Equipment Efficiencies, Verification, and Labeling Requirements > 6.4.1.5 Labeling > 6.4.1.5.2 Packaged Terminal Air Conditioners
G3.1.2.1 Normative Appendix G Performance Rating Method, Equipment Efficiencies
0.576 FL 0.549 IPLV .IP Table G3.5.4 Performance Rating Method Electrically Operated Packaged Terminal Air Conditioners , Packaged ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Illinois > Normative Appendix G Performance Rating Method > G3 Calculation of the Proposed Design and Baseline Building Performance > G3.1 Building Performance Calculations > G3.1.2 General Baseline HVAC System Requirements > G3.1.2.1 Equipment Efficiencies
3.3 Definitions, Abbreviations, and Acronyms, Abbreviations and Acronyms
PTAC packaged terminal air conditioner PTHP packaged terminal heat pump PUE power use effectiveness R R-value ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Illinois > 3 Definitions, Abbreviations, and Acronyms > 3.3 Abbreviations and Acronyms
6.3 Heating, Ventilating, and Air Conditioning, Simplified Approach Option for HVAC Systems
meeting the requirements shown in Table 6.8.1-1 (air conditioners), Table 6.8.1-2 (heat pumps), or Table 6.8.1-4 (packaged terminal and room ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Illinois > 6 Heating, Ventilating, and Air Conditioning > 6.3 Simplified Approach Option for HVAC Systems
12 Normative References
AHRI 210/240-2008 with Addendum 1 and 2 Unitary Air Conditioning and Air-Source Heat Pump Equipment AHRI 310/380-2004 Packaged Terminal Air ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Illinois > 12 Normative References
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING