1910.430(i)(1)
Equipment used with oxygen or mixtures containing over forty percent (40%) by volume oxygen shall be designed for oxygen service.
1910.430(i)(2)
Components (except umbilicals) exposed to oxygen or mixtures containing over forty percent (40%) by volume oxygen shall be cleaned of flammable materials before use.
1910.430(i)(3)
Oxygen systems over 125 psig and compressed air systems over 500 psig shall have slow-opening shut-off valves.

Related Code Sections

1910.430(i) Commercial Diving Operations, Oxygen Safety
Equipment used with oxygen or mixtures containing over forty percent (40%) by volume oxygen shall be designed for oxygen service ...
1910.104(b)(6)(iii) Hazardous Materials, ASME Containers
Bulk oxygen storage containers designed and constructed in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII - Unfired Pressure ...
1910.104(b)(6)(i) Hazardous Materials, General
Bulk oxygen storage containers, regardless of design pressure shall be equipped with safety relief devices as required by the ASME code or the DOT ...
1910.104(b)(6)(v) Hazardous Materials, Reliability
All safety relief devices shall be so designed or located that moisture cannot collect and freeze in a manner which would interfere with proper ...
1910.104(b)(6) Hazardous Materials, Safety Relief Devices
Bulk oxygen storage containers, regardless of design pressure shall be equipped with safety relief devices as required by the ASME code or the DOT ...