• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2209.6 Overpressure Protection

NYC Fire Code 2014 > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2209 Hydrogen Motor Fuel-Dispensing and Generating Facilities > 2209.6 Overpressure Protection
JUMP TO FULL CODE CHAPTER
Dispensing systems shall be equipped with an overpressure protection device set at 140 percent of the service pressure of the fueling nozzle it supplies.

Related Code Sections


Section 416 Gas Piping Installations, Overpressure Protection Devices
Overpressure protection devices shall be provided in accordance with this section to prevent the pressure in the piping system from exceeding ...
NYC Fuel Gas Code 2014 > 4 Gas Piping Installations > 416 Overpressure Protection Devices
Section 416 Gas Piping Installations, Overpressure Protection Devices
at a gas pressure of 14 inches w.c. (3.49 kPa) or less, overpressure protection devices shall be installed. Piping systems serving appliances designed ...
NYC Fuel Gas Code 2022 > 4 Gas Piping Installations > 416 Overpressure Protection Devices
416.3 Gas Piping Installations, Devices
to the control piping of one device will not render both the regulator and the overpressure protection device inoperative ...
NYC Fuel Gas Code 2022 > 4 Gas Piping Installations > 416 Overpressure Protection Devices > 416.3 Devices
416.4 Gas Piping Installations, Where Required
A pressure-relieving or pressure-limiting device shall not be required where: (1) the gas does not contain materials that could seriously interfere ...
NYC Fuel Gas Code 2014 > 4 Gas Piping Installations > 416 Overpressure Protection Devices > 416.4 Where Required
416.5 Gas Piping Installations, Devices
External control piping shall be protected from falling objects, excavations ...
NYC Fuel Gas Code 2014 > 4 Gas Piping Installations > 416 Overpressure Protection Devices > 416.5 Devices
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING