1926.1003(b) Overhead Protection
JUMP TO FULL CODE CHAPTER
Overhead protection. When overhead protection is installed on wheel-type agricultural or industrial tractors used in construction work, it shall meet the requirements of this paragraph. The overhead protection may be constructed of a solid material. When grid or mesh is used, the largest permissible opening shall be such that the maximum circle that can be inscribed between the elements of the grid or mesh is 1.5 in. (38 mm) in diameter. The overhead protection shall not be installed in such a way as to become a hazard in the case of upset.
Related Code Sections
1926.1003(b) Rollover Protective Structures; Overhead Protection, Overhead Protection
Overhead protection. When overhead protection is installed on wheel-type agricultural or industrial tractors used in construction work, it shall meet ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1003 Overhead Protection for Operators of Agricultural and Industrial Tractors > 1926.1003(b) Overhead Protection
Subpart W Rollover Protective Structures; Overhead Protection
Authority : Section 3704 of the Contract Work Hours and Safety Standards Act (40 U.S.C. 3701); Sections 4, 6, and 8 of the Occupational Safety ...
1926.1003(f) Rollover Protective Structures; Overhead Protection, Performance Requirements
deformation due to impact of the sphere shall not enter the protected zone as illustrated in Figures W-25, W-26, and W-28 ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1003 Overhead Protection for Operators of Agricultural and Industrial Tractors > 1926.1003(f) Performance Requirements
1926.1003(g) Rollover Protective Structures; Overhead Protection, Source of Standard
with overhead protection -- test procedures and performance requirements"), which pertain to overhead protection requirements. The SAE standard appears ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1003 Overhead Protection for Operators of Agricultural and Industrial Tractors > 1926.1003(g) Source of Standard
1926.1003(a)(1) Rollover Protective Structures; Overhead Protection, Purpose
When overhead protection is provided on wheel-type agricultural and industrial tractors, the overhead protection shall be designed and installed ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1003 Overhead Protection for Operators of Agricultural and Industrial Tractors > 1926.1003(a) General > 1926.1003(a)(1) Purpose