• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.501(b)(9) Overhand Bricklaying and Related Work

OSHA 1926 Construction > M Fall Protection > 1926.501 Duty to Have Fall Protection > 1926.501(b) > 1926.501(b)(9) Overhand Bricklaying and Related Work
JUMP TO FULL CODE CHAPTER

1926.501(b)(9)(i)

Except as otherwise provided in paragraph (b) of this section, each employee performing overhand bricklaying and related work 6 feet (1.8 m) or more above lower levels, shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or shall work in a controlled access zone.

1926.501(b)(9)(ii)

Each employee reaching more than 10 inches (25 cm) below the level of the walking/working surface on which they are working, shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system.

Note: Bricklaying operations performed on scaffolds are regulated by subpart L - Scaffolds of this part.

Related Code Sections


1926.501(b)(9) Fall Protection, Overhand Bricklaying and Related Work
Except as otherwise provided in paragraph (b) of this section, each employee performing overhand bricklaying and related work 6 feet (1.8 m) or more ...
OSHA 1926 Construction > M Fall Protection > 1926.501 Duty to Have Fall Protection > 1926.501(b) > 1926.501(b)(9) Overhand Bricklaying and Related Work
1926.502(g)(2) Fall Protection,
When used to control access to areas where overhand bricklaying and related work are taking place ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(g) Controlled Access Zones > 1926.502(g)(2)
1926.502(g) Fall Protection, Controlled Access Zones
overhand bricklaying and related work at the working edge and shall be approximately parallel to the working edge ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(g) Controlled Access Zones
1926.502(j) Fall Protection, Protection From Falling Objects
bricklaying and related work: No materials or equipment ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(j) Protection From Falling Objects
1926.502 Fall Protection, Fall Protection Systems Criteria and Practices
in overhand bricklaying or related work shall be permitted in the controlled access zone ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING