• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E4207.3.2 Over the Low-Voltage Contact Limit but Not Over 150 Volts

2012 Virginia Residential Code > 42 Swimming Pools > E4207 Storable Swimming Pools > E4207.3 Luminaires > E4207.3.2 Over the Low-Voltage Contact Limit but Not Over 150 Volts
JUMP TO FULL CODE CHAPTER

A lighting assembly without a transformer or power supply, and with the luminaire lamp(s) operating at over the low-voltage contact limit, but not over 150 volts, shall be permitted to be cord and plug-connected where the assembly is listed as an assembly for the purpose and complies with all of the following:

  1. It has an impact-resistant polymeric lens and luminaire body.
  2. A ground-fault circuit interrupter with open neutral conductor protection is provided as an integral part of the assembly.
  3. The luminaire lamp is permanently connected to the ground-fault circuit interrupter with open-neutral protection.
  4. It complies with the requirements of Section E4206.4.
  5. It has no exposed metal parts.

Related Code Sections


E4207.3.2 Swimming Pools, Over the Low-Voltage Contact Limit but Not Over 150 Volts
A lighting assembly without a transformer or power supply, and with the luminaire lamp(s) operating at over the low-voltage contact limit ...
2012 Virginia Residential Code > 42 Swimming Pools > E4207 Storable Swimming Pools > E4207.3 Luminaires > E4207.3.2 Over the Low-Voltage Contact Limit but Not Over 150 Volts
E4207.3.2 Swimming Pools, Over the Low-Voltage Contact Limit but Not Over 150 Volts
A lighting assembly without a transformer or power supply, and with the luminaire lamp(s) operating at over the low-voltage contact limit ...
2015 Virginia Residential Code > 42 Swimming Pools > E4207 Storable Swimming Pools, Storable Spas, and Storable Hot Tubs > E4207.3 Luminaires > E4207.3.2 Over the Low-Voltage Contact Limit but Not Over 150 Volts
E4206.4.1 Swimming Pools, Maximum Voltage
Luminaires shall not be installed for operation on supply circuits over 150 volts between conductors ...
2012 Virginia Residential Code > 42 Swimming Pools > E4206 Equipment Installation > E4206.4 Underwater Luminaires > E4206.4.1 Maximum Voltage
E4206.4.1 Swimming Pools, Maximum Voltage
Luminaires shall not be installed for operation on supply circuits over 150 volts between conductors. [680.23(A)(4)] ...
2015 Virginia Residential Code > 42 Swimming Pools > E4206 Equipment Installation > E4206.4 Underwater Luminaires > E4206.4.1 Maximum Voltage
E4206.4 Swimming Pools, Underwater Luminaires
be installed in the branch circuit supplying luminaires operating at more than the low-voltage contact limit, such that there is no shock hazard during ...
2015 Virginia Residential Code > 42 Swimming Pools > E4206 Equipment Installation > E4206.4 Underwater Luminaires
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE