Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.263(l) Ovens

OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens
JUMP TO FULL CODE CHAPTER
-

1910.263(l)(1) General Location

1910.263(l)(1)(i)

[Reserved]

1910.263(l)(1)(iii)

[Reserved]

1910.263(l)(1)(iv)

[Reserved]

1910.263(l)(1)(v)

[Reserved]

1910.263(l)(1)(vi)

[Reserved]

1910.263(l)(1)(vii)

Ovens shall be located so that possible fire or explosion will not expose groups of persons to possible injury. For this reason ovens shall not adjoin lockers, lunch or sales rooms, main passageways, or exits.

1910.263(l)(1)(ii)

[Reserved]

1910.263(l)(2)

[Reserved]

1910.263(l)(3) Safeguards of Mechanical Parts

1910.263(l)(3)(i)

Emergency stop buttons shall be provided on mechanical ovens near the point where operators are stationed.

1910.263(l)(3)(iii)

Main shutoff valves, operable separately from any automatic valve, shall be provided to permit turning off the fuel or steam in case of an emergency.

1910.263(l)(3)(iii)(a)

Main shutoff valves shall be located so that explosions, fires, etc. will not prevent access to these valves.

1910.263(l)(3)(iii)(b)

Main shutoff valves shall be locked in the closed position when men must enter the oven or when the oven is not in service.

1910.263(l)(3)(ii)

All piping at ovens shall be tested to be gastight.

1910.263(l)(4)

[Reserved]

1910.263(l)(5)

[Reserved]

1910.263(l)(6)

[Reserved]

1910.263(l)(7)

[Reserved]

1910.263(l)(8) Electrical Heating Equipment

1910.263(l)(8)(i)

[Reserved]

1910.263(l)(8)(iii)

A main disconnect switch or circuit breaker shall be provided. This switch or circuit breaker shall be so located that it can be reached quickly and safely. The main switch or circuit breaker shall have provisions for locking it in the open position if any work on the electrical equipment or inside the oven must be performed.

1910.263(l)(8)(ii)

[Reserved]

1910.263(l)(9) General Requirements

1910.263(l)(9)(i)

Protecting devices shall be properly maintained and kept in working order.

1910.263(l)(9)(iii)

1910.263(l)(9)(iii)(a)

Protection of gas pilot lights shall be provided when it is impracticable to protect the main flame of the burner and where the pilot flame cannot contact the flame electrode without being in the path of the main flame of the burner. Failure of any gas pilot shall automatically shut off the fuel supply to the burner.

1910.263(l)(9)(iii)(b)

Ovens with multiple burners shall be equipped with individual atmospheric pilot lights where there is sufficient secondary air in the baking chamber and where gas is available; or else each burner shall be equipped with an electric spark-type ignition device.

1910.263(l)(9)(iv)

Burners of a capacity exceeding 150,000 B.t.u. per hour equipped with electric ignition shall be protected in addition by quick-acting combustion safeguards.

1910.263(l)(9)(iv)(a)

The high-tension current for any electric spark-type ignition device shall originate in a power supply line which is interlocked with the fuel supply for the oven in such a way that in case of current failure both the source of electricity to the high-tension circuits and the fuel supply shall be turned off simultaneously.

1910.263(l)(9)(iv)(b)

[Reserved]

1910.263(l)(9)(iv)(c)

Combustion safeguards used in connection with electric ignition systems on ovens shall be so designed as to prevent an explosive mixture from accumulating inside the oven before ignition has taken place.

1910.263(l)(9)(ix)

[Reserved]

1910.263(l)(9)(v)

When fuel is supplied and used at line pressure, safety shutoff valves shall be provided in the fuel line leading to the burner.

1910.263(l)(9)(v)(a)

When fuel is supplied in excess of line pressure, safety shutoff valves shall be provided in the fuel line leading to the burners, unless the fuel supply lines are equipped with other automatic valves which will prevent the flow of fuel when the compressing equipment is stopped.

1910.263(l)(9)(v)(b)

The safety shutoff valve shall be positively tight and shall be tested at least twice monthly.

1910.263(l)(9)(v)(c)

[Reserved]

1910.263(l)(9)(v)(d)

[Reserved]

1910.263(l)(9)(v)(e)

A safety shutoff valve shall require manual operation for reopening after it has closed, or the electric circuit shall be so arranged that it will require a manual operation for reopening the safety shutoff valve.

1910.263(l)(9)(v)(f)

Manual reset-type safety shutoff valves shall be so arranged that they cannot be locked in an open position by external means.

1910.263(l)(9)(v)(g)

Where blowers are used for supplying the air for combustion the safety shutoff valve shall be interlocked so that it will close in case of air failure.

1910.263(l)(9)(v)(h)

Where gas or electric ignition is used, the safety shutoff valve shall close in case of ignition failure. On burners equipped with combustion safeguards, the valve shall close in case of burner flame failure.

1910.263(l)(9)(vi)

One main, manually operated, fuel shutoff valve shall be provided on each oven, and shall be located ahead of all other valves in the system.

1910.263(l)(9)(vii)

All individual gas or oil burners with a heating capacity over 150,000 B.t.u. per hour shall be protected by a safeguard which is actuated by the flame and which will react to flame failure in a time interval not to exceed 2 seconds. All safeguards, once having shut down a gas or oil burner, shall require manual resetting and starting of the burner or burners.

1910.263(l)(9)(viii)

Any space in an oven (except direct fired ovens) which could be filled with an explosive mixture shall be protected by explosion vents. Explosion vents shall be made of minimum weight consistent with adequate insulation.

1910.263(l)(9)(viii)(a)

Explosion doors which have a substantial weight shall be attached by chains or similar means to prevent flying parts from injuring the personnel in case of an explosion.

1910.263(l)(9)(viii)(b)

Where explosion vents are so located that flying parts or gases might endanger the personnel working on or near the oven, internal or external protecting means shall be provided in the form of heavily constructed shields or deflectors made from noncombustible material.

1910.263(l)(9)(viii)(c)

Specifically exempted from the provisions of paragraph paragraph (l)(8)(viii) of this section are heating systems on ovens in which the fuel is admitted only to enclosed spaces which shall have been tested to prove that their construction will resist repeated explosions without deformation are exempt from the requirements of paragraph (l)(8)(viii)(a) and (b) of this section.

1910.263(l)(9)(x)

[Reserved]

1910.263(l)(9)(xi)

Where the gas supply pressure is substantially higher than that at which the burners of an oven are designed to operate, a gas pressure regulator shall be employed.

1910.263(l)(9)(xi)(a)

[Reserved]

1910.263(l)(9)(xi)(b)

[Reserved]

1910.263(l)(9)(xi)(c)

[Reserved]

1910.263(l)(9)(xi)(d)

A relief valve shall be placed on the outlet side of gas pressure regulators where gas is supplied at high pressure. The discharge from this valve shall be piped to the outside of the building.

1910.263(l)(9)(ii)

All safety devices on ovens shall be inspected at intervals of not less than twice a month by an especially appointed, properly instructed bakery employee, and not less than once a year by representatives of the oven manufacturers.

1910.263(l)(10) Direct-Fired Ovens

1910.263(l)(10)(i)

Direct-fired ovens shall be afeguarded against failure of fuel, air, or ignition.

1910.263(l)(10)(ii)

To prevent the possible accumulation of explosive gases from being ignited after a shutdown, all direct-fired ovens with a heating capacity over 150,000 B.t.u. per hour shall be ventilated before the ignition system, combustion air blower, and the fuel can be turned on. The preventilation shall insure at least four complete changes of atmosphere in the baking chamber by discharging the oven atmosphere to the outside of the building and entraining fresh air into it. The preventilation shall be repeated whenever the heating equipment is shut down by a safety device.

1910.263(l)(11) Direct Recirculating Ovens

1910.263(l)(11)(i)

Each circulating fan in direct recirculating ovens shall be interconnected with the burner in such a manner that the fuel is shut off by a safety valve when the fan is not running.

1910.263(l)(11)(ii)

The flame of the burner or burners in direct recirculating ovens shall be protected by a quick-acting flame-sensitive safeguard which will automatically shut off the fuel supply in case of burner failure.

1910.263(l)(12)

[Reserved]

1910.263(l)(13)

[Reserved]

1910.263(l)(14)

[Reserved]

1910.263(l)(15) Indirect Recirculating Ovens

1910.263(l)(15)(i)

[Reserved]

1910.263(l)(15)(iii)

Duct systems (in ovens) operating under pressure shall be tested for tightness in the initial starting of the oven and also at intervals not farther apart than 6 months.

[39 FR 23502, June 27, 1974, as amended at 43 FR 49765, Oct. 24, 1978; 43 FR 51760, Nov. 7, 1978; 61 FR 9227, March 7, 1996]

1910.263(l)(15)(ii)

[Reserved]

Related Code Sections


1910.263(l) Special Industries, Ovens
] Ovens shall be located so that possible fire or explosion will not expose groups of persons to possible injury. For this reason ovens shall ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens
1910.1029(e)(1)(iii)(m) Toxic and Hazardous Substances, Oven Patcher
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions > 1910.1029(e) Exposure Monitoring and Measurement > 1910.1029(e)(1) Monitoring Program > 1910.1029(e)(1)(iii) > 1910.1029(e)(1)(iii)(m) Oven Patcher
1910.1028(a)(2)(vii) Toxic and Hazardous Substances, Coke Oven Batteries
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(a) Scope and Application > 1910.1028(a)(2) This Section Does Not Apply To: > 1910.1028(a)(2)(vii) Coke Oven Batteries
1910.263(l)(15) Special Industries, Indirect Recirculating Ovens
[Reserved] Duct systems (in ovens) operating under ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens > 1910.263(l)(15) Indirect Recirculating Ovens
1910.1029(f)(1)(i) Toxic and Hazardous Substances, Existing Coke Oven Batteries
coke oven batteries at the earliest possible time, but not later than January 20, 1980, except to the extent that the employer can establish ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1029 Coke Oven Emissions > 1910.1029(f) Methods of Compliance > 1910.1029(f)(1) Priority of Compliance Methods > 1910.1029(f)(1)(i) Existing Coke Oven Batteries
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING