• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1602.9.1 Outside Hose Bibbs

Uniform Plumbing Code 2018 of Nevada > 16 Nonpotable Rainwater Catchment Systems > 1602.0 Nonpotable Rainwater Catchment Systems > 1602.9 Design and Installation > 1602.9.1 Outside Hose Bibbs
JUMP TO FULL CODE CHAPTER
Outside hose bibbs shall be allowed on rainwater piping systems. Hose bibbs supplying rainwater shall be marked with the words: "CAUTION: NONPOTABLE WATER, DO NOT DRINK" and Figure 1602.9.1
FIGURE 1602.9.1

Related Code Sections


1602.9.1 Nonpotable Rainwater Catchment Systems, Outside Hose Bibbs
Outside hose bibbs shall be allowed on rainwater piping systems. Hose bibbs supplying rainwater shall be marked with the words: "CAUTION: NONPOTABLE ...
Uniform Plumbing Code 2018 of Nevada > 16 Nonpotable Rainwater Catchment Systems > 1602.0 Nonpotable Rainwater Catchment Systems > 1602.9 Design and Installation > 1602.9.1 Outside Hose Bibbs
1505.9 Alternate Water Sources for Nonpotable Applications, Hose Bibbs
Hose bibbs shall not be allowed on reclaimed (recycled) water piping systems located in areas accessible to the public. Access to reclaimed (recycled ...
Uniform Plumbing Code 2018 of Nevada > 15 Alternate Water Sources for Nonpotable Applications > 1505.0 Reclaimed (Recycled) Water Systems > 1505.9 Hose Bibbs
P2903.10 Water Supply and Distribution, Hose Bibb
Hose bibbs subject to freezing, including the "frostproof" type, shall be equipped with an accessible stop-and-waste-type valve inside the building ...
Residential Code 2012 of Nevada > 29 Water Supply and Distribution > P2903 Water-Supply System > P2903.10 Hose Bibb
P2903.10 Water Supply and Distribution, Hose Bibb
Hose bibbs subject to freezing, including the "frostproof" type, shall be equipped with an accessible stop-and-waste-type valve inside the building ...
Residential Code 2018 of Nevada > 29 Water Supply and Distribution > P2903 Water Supply System > P2903.10 Hose Bibb
M 102.5 Peak Water Demand Calculator, Continuous Supply Demand
Continuous supply demands in gallons per minute (gpm) for lawn sprinklers, air conditioners, hose bibbs, etc., shall be added to the total estimated ...
Uniform Plumbing Code 2018 of Nevada > M Peak Water Demand Calculator > M 102.0 Demand Load > M 102.5 Continuous Supply Demand
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING