3314.7 Outrigger Beams
JUMP TO FULL CODE CHAPTER
Outrigger beams shall be made of structural metal or equivalent strength material and shall be restrained to prevent movement.
The overhang of outrigger beams shall not exceed that specified by the design and the inboard length of beam shall be at least one and one-half times the outboard length unless otherwise designed by a registered design professional.
Outrigger beams shall be placed so that the suspension ropes will hang vertically.
Suspension ropes shall be securely fastened to the outrigger beams by steel shackles, thimbles, or equivalent means.
Related Code Sections
3314.14.1 Safeguards During Construction or Demolition, Outrigger Beams
The fulcrum point of the beam shall rest on a secure bearing at least 6 inches (152 mm) in each horizontal dimension. The beam shall be secured ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.14 Outrigger Scaffolds (Thrust Out) > 3314.14.1 Outrigger Beams
3314.14.1 Safeguards During Construction or Demolition, Outrigger Beams
The fulcrum point of the beam shall rest on a secure bearing at least 6 inches (152 mm) in each horizontal dimension. The beam shall be secured ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.14 Outrigger Scaffolds (Thrust Out) > 3314.14.1 Outrigger Beams
3314.14.1 Safeguards During Construction or Demolition, Outrigger Beams
The fulcrum point of the beam shall rest on a secure bearing at least 6 inches (152 mm) in each horizontal dimension. The beam shall be secured ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.14 Outrigger Scaffolds (Thrust Out) > 3314.14.1 Outrigger Beams
3314.10.3 Safeguards During Construction or Demolition, Outrigger Beam Location
Outrigger beams shall be placed perpendicular to the face of the building or structure. Exception: Where a licensed rigger or registered design ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.10 Suspended Scaffold > 3314.10.3 Outrigger Beam Location
3314.10.4 Safeguards During Construction or Demolition, Outrigger Beam Stabilization
The inboard ends of the suspended scaffold outrigger beam shall be stabilized by bolts or other direct connections to the floor or roof deck ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.10 Suspended Scaffold > 3314.10.4 Outrigger Beam Stabilization