• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

603.5.7 Outlets With Hose Attachments

Uniform Plumbing Code 2018 of Nevada > 6 Water Supply and Distribution > 603.0 Cross-Connection Control > 603.5 Specific Requirements > 603.5.7 Outlets With Hose Attachments
JUMP TO FULL CODE CHAPTER
Potable water outlets with hose attachments, other than water heater drains, boiler drains, and clothes washer connections, shall be protected by a nonremovable hose bibb-type backflow preventer, a nonremovable hose bibb-type vacuum breaker, or by an atmospheric vacuum breaker installed not less than 6 inches (152 mm) above the highest point of usage located on the discharge side of the last valve. In climates where freezing temperatures occur, a listed self-draining frost-proof hose bibb with an integral backflow preventer or vacuum breaker shall be used.

Related Code Sections


603.5.7 Water Supply and Distribution, Outlets With Hose Attachments
Potable water outlets with hose attachments, other than water heater drains, boiler drains, and clothes washer connections, shall be protected ...
Uniform Plumbing Code 2018 of Nevada > 6 Water Supply and Distribution > 603.0 Cross-Connection Control > 603.5 Specific Requirements > 603.5.7 Outlets With Hose Attachments
8.17.5 Installation Requirements, Hose Connections
runs. Where the residual pressure at a 1 1 / 2 in. (40 mm) outlet on a hose connection exceeds 100 psi (7 bar), an approved pressure-regulating device ...
Standard for the Installation of Sprinkler Systems 2016 of Nevada > 8 Installation Requirements > 8.17 System Attachments > 8.17.5 Hose Connections
P2902.4.3 Water Supply and Distribution, Hose Connection
breaker or a permanently attached hose connection vacuum breaker. Exceptions: This section shall not apply to water heater and boiler drain valves ...
Residential Code 2012 of Nevada > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.4 Protection of Potable Water Outlets > P2902.4.3 Hose Connection
P2902.4.3 Water Supply and Distribution, Hose Connection
breaker, a pressure vacuum-breaker assembly or a permanently attached hose connection vacuum breaker. Exceptions: This section shall not apply ...
Residential Code 2018 of Nevada > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.4 Protection of Potable Water Outlets > P2902.4.3 Hose Connection
(E) Equipment for General Use, Flush Mounting With Faceplate
The enclosure for a receptacle installed in an outlet box flush-mounted in a finished surface shall be made weatherproof by means of a weatherproof ...
National Electrical Code 2017 of Nevada > 4 Equipment for General Use > 406 Receptacles, Cord Connectors, and Attachment Plugs (Caps) > 406.9 Receptacles in Damp or Wet Locations > (E) Flush Mounting With Faceplate
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING