• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(A) Outdoors

National Electrical Code 2020 of Illinois > 3 Wiring Methods and Materials > 366 Auxiliary Gutters > 366.120 Marking > (A) Outdoors
JUMP TO FULL CODE CHAPTER
Nonmetallic auxiliary gutters installed outdoors shall have the following markings:
  1. Suitable for exposure to sunlight
  2. Suitable for use in wet locations
  3. Installed conductor insulation temperature rating

Related Code Sections


(2) General, Outdoor
Outdoor installations shall comply with 110.26(E)(2)(a) through (E)(2)(c). (a) Installation Requirements. Outdoor electrical equipment shall ...
National Electrical Code 2020 of Illinois > 1 General > 110 Requirements for Electrical Installations > 110.26 Spaces About Electrical Equipment > (E) Dedicated Equipment Space > (2) Outdoor
(2) General, Outdoor
Outdoor installations shall comply with 110.26(E)(2)(a) through (c). (a) Installation Requirements. Outdoor electrical equipment shall ...
National Electrical Code 2017 of Illinois > 1 General > 110 Requirements for Electrical Installations > 110.26 Spaces About Electrical Equipment > (E) Dedicated Equipment Space > (2) Outdoor
(1) Wiring Methods and Materials, Outdoors
Nonmetallic auxiliary gutters shall be permitted to be installed outdoors where listed and marked as suitable for the purpose ...
National Electrical Code 2017 of Illinois > 3 Wiring Methods and Materials > 366 Auxiliary Gutters > 366.10 Uses Permitted > (B) Nonmetallic Auxiliary Gutters > (1) Outdoors
(1) Wiring Methods and Materials, Outdoors
Nonmetallic auxiliary gutters shall be permitted to be installed outdoors where listed and marked as suitable for the purpose ...
National Electrical Code 2020 of Illinois > 3 Wiring Methods and Materials > 366 Auxiliary Gutters > 366.10 Uses Permitted > (B) Nonmetallic Auxiliary Gutters > (1) Outdoors
(2) Special Occupancies, Outdoors
Equipotential planes shall be installed in concrete slabs where metallic equipment is located that may become energized and is accessible to livestock ...
National Electrical Code 2020 of Illinois > 5 Special Occupancies > 547 Agricultural Buildings > 547.10 Equipotential Planes and Bonding of Equipotential Planes > (A) Where Required > (2) Outdoors
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING