• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

6004.3.3 Outdoor Storage Weather Protection for Portable Tanks and Cylinders

Fire Code 2018 of Colorado > 60 Highly Toxic and Toxic Materials > 6004 Highly Toxic and Toxic Compressed Gases > 6004.3 Outdoor Storage and Use > 6004.3.3 Outdoor Storage Weather Protection for Portable Tanks and Cylinders
JUMP TO FULL CODE CHAPTER
Weather protection in accordance with Section 5004.13 shall be provided for portable tanks and cylinders located outdoors and not within gas cabinets or exhausted enclosures. The storage area shall be equipped with an approved automatic sprinkler system in accordance with Section 903.3.1.1.
Exception: An automatic sprinkler system is not required where:
  1. All materials under the weather protection structure, including hazardous materials and the containers in which they are stored, are non-combustible.
  2. The weather protection structure is located not less than 30 feet (9144 mm) from combustible materials or structures or is separated from such materials or structures using a fire barrier complying with Section 6004.3.2.1.1.

Related Code Sections


6004.3.3 Highly Toxic and Toxic Materials, Outdoor Storage Weather Protection for Portable Tanks and Cylinders
Weather protection in accordance with Section 5004.13 shall be provided for portable tanks and cylinders located outdoors and not within gas cabinets ...
Fire Code 2021 of Colorado > 60 Highly Toxic and Toxic Materials > 6004 Highly Toxic and Toxic Compressed Gases > 6004.3 Outdoor Storage and Use > 6004.3.3 Outdoor Storage Weather Protection for Portable Tanks and Cylinders
6004.3.3 Highly Toxic and Toxic Materials, Outdoor Storage Weather Protection for Portable Tanks and Cylinders
Weather protection in accordance with Section 5004.13 shall be provided for portable tanks and cylinders located outdoors and not within gas cabinets ...
Fire Code 2018 of Colorado > 60 Highly Toxic and Toxic Materials > 6004 Highly Toxic and Toxic Compressed Gases > 6004.3 Outdoor Storage and Use > 6004.3.3 Outdoor Storage Weather Protection for Portable Tanks and Cylinders
5704.4.7 Flammable and Combustible Liquids, Weather Protection
Weather protection for outdoor storage shall be in accordance with Section 5004.13 ...
Fire Code 2021 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.4 Outdoor Storage of Containers and Portable Tanks > 5704.4.7 Weather Protection
5704.4.7 Flammable and Combustible Liquids, Weather Protection
Weather protection for outdoor storage shall be in accordance with Section 5004.13 ...
Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5704 Storage > 5704.4 Outdoor Storage of Containers and Portable Tanks > 5704.4.7 Weather Protection
6004.2.2.7.5 Highly Toxic and Toxic Materials, Portable Tanks and Cylinders
The maximum flow rate of release for portable tanks and cylinders shall be calculated based on the total release from the cylinder or tank within ...
Fire Code 2018 of Colorado > 60 Highly Toxic and Toxic Materials > 6004 Highly Toxic and Toxic Compressed Gases > 6004.2 Indoor Storage and Use > 6004.2.2 General Indoor Requirements > 6004.2.2.7 Treatment Systems > 6004.2.2.7.5 Portable Tanks and Cylinders
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING