• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 414.6 Outdoor Storage, Dispensing and Use

Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use
JUMP TO FULL CODE CHAPTER
The outdoor storage, dispensing and use of hazardous materials shall be in accordance with the International Fire Code.

[F] 414.6.1 Weather Protection

Where weather protection is provided for sheltering outdoor hazardous material storage or use areas, such areas shall be considered outdoor storage or use where the weather protection structure complies with Sections 414.6.1.1 through 414.6.1.3.

[F] 414.6.1.1 Walls

Walls shall not obstruct more than one side of the structure.
Exception: Walls shall be permitted to obstruct portions of multiple sides of the structure, provided that the obstructed area is not greater than 25 percent of the structure's perimeter.

[F] 414.6.1.2 Separation Distance

The distance from the structure to buildings, lot lines, public ways or means of egress to a public way shall be not less than the distance required for an outside hazardous material storage or use area without weather protection.

[F] 414.6.1.3 Noncombustible Construction

The overhead structure shall be of approved noncombustible construction with a maximum area of 1,500 square feet (140 m2).
Exception: The maximum area is permitted to be increased as provided by Section 506.

Related Code Sections


414.6 Special Detailed Requirements Based on Occupancy and Use, Outdoor Storage, Dispensing and Use
The outdoor storage, dispensing and use of hazardous materials shall be in accordance with the International Fire Code ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use
414.6 Special Detailed Requirements Based on Occupancy and Use, Outdoor Storage, Dispensing and Use
The outdoor storage, dispensing and use of hazardous materials shall be in accordance with the International Fire Code ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use
414.6.1.1 Special Detailed Requirements Based on Occupancy and Use, Walls
Walls shall not obstruct more than one side of the structure. Exception: Walls shall be permitted to obstruct portions of multiple sides ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use > 414.6.1 Weather Protection > 414.6.1.1 Walls
414.6.1.3 Special Detailed Requirements Based on Occupancy and Use, Noncombustible Construction
The overhead structure shall be of approved noncombustible construction with a maximum area of 1,500 square feet (140 m 2 ). Exception: The ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use > 414.6.1 Weather Protection > 414.6.1.3 Noncombustible Construction
414.6.1.3 Special Detailed Requirements Based on Occupancy and Use, Noncombustible Construction
The overhead structure shall be of approved noncombustible construction with a maximum area of 1,500 square feet (140 m 2 ). Exception: The ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use > 414.6.1 Weather Protection > 414.6.1.3 Noncombustible Construction
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING