552.59 Outdoor Outlets, Fixtures, Including Luminaires, Air-Cooling Equipment, and So On
Go To Full Code Chapter
(A) Listed for Outdoor Use
Outdoor fixtures, including luminaires, and equipment shall be listed for outdoor use. Outdoor receptacle outlets shall be in accordance with 406.9(A) and (B). Switches and circuit breakers installed outdoors shall comply with 404.4.
(B) Outside Heating Equipment, Air-Conditioning Equipment, or Both
A park trailer provided with a branch circuit designed to energize outside heating equipment or air-conditioning equipment, or both, located outside the park trailer, other than room air conditioners, shall have such branch-circuit conductors terminate in a listed outlet box or disconnecting means located on the outside of the park trailer. A safety label with the word WARNING in minimum 6 mm (1/4 in.) high letters and body text in minimum 3 mm (1/8 in.) high letters on a contrasting background shall be affixed within 150 mm (6 in.) from the listed box or disconnecting means and shall read as follows:
WARNING
THIS CONNECTION IS FOR HEATING AND/OR AIR-CONDITIONING EQUIPMENT. THE BRANCH CIRCUIT IS RATED AT NOT MORE THAN ____AMPERES, AT____VOLTS, 60 HZ,____ CONDUCTOR AMPACITY. A DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHT OF THE EQUIPMENT. EXCEEDING THE CIRCUIT RATING MAY CAUSE A FIRE AND RESULT IN DEATH OR SERIOUS INJURY.
THIS CONNECTION IS FOR HEATING AND/OR AIR-CONDITIONING EQUIPMENT. THE BRANCH CIRCUIT IS RATED AT NOT MORE THAN ____AMPERES, AT____VOLTS, 60 HZ,____ CONDUCTOR AMPACITY. A DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHT OF THE EQUIPMENT. EXCEEDING THE CIRCUIT RATING MAY CAUSE A FIRE AND RESULT IN DEATH OR SERIOUS INJURY.
The correct voltage and ampere rating shall be given.
Related Code Sections
552.59 Special Occupancies, Outdoor Outlets, Fixtures, Including Luminaires, Air-Cooling Equipment, and So On
Outdoor fixtures, including luminaires, and equipment shall be listed for outdoor use. Outdoor receptacle outlets shall be in accordance with 406.9(A ...
(C) Special Occupancies, Outdoor Outlets, Luminaires, Air-Cooling Equipment, and So On
Outdoor luminaires and other equipment shall be listed for outdoor use ...
550.20 Special Occupancies, Outdoor Outlets, Luminaires, Air-Cooling Equipment, and So Forth
Outdoor luminaires and equipment shall be listed for wet locations or outdoor use. Outdoor receptacles shall comply with 406.9. Where located ...
552.54 Special Occupancies, Luminaires
Outdoor luminaires and other equipment shall be listed for outdoor use or wet locations ...
Section M1413 Heating and Cooling Equipment and Appliances, Evaporative Cooling Equipment
Evaporative cooling equipment and appliances shall comply with UL 1995 or UL/CSA/ANCE 60335-2-40 and shall be installed: In accordance ...