• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(E) Outdoor Outlets

National Electrical Code 2020 of Minnesota > 2 Wiring and Protection > 210 Branch Circuits > 210.52 Dwelling Unit Receptacle Outlets > (E) Outdoor Outlets
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Outdoor receptacle outlets shall be installed in accordance with 210.52(E)(1) through (E)(3).
Informational Note: See 210.8(A)(3).

(1) One-Family and Two-Family Dwellings

For a one-family dwelling and each unit of a two-family dwelling that is at grade level, at least one receptacle outlet readily accessible from grade and not more than 2.0 m (61/2 ft) above grade level shall be installed at the front and back of the dwelling.

(2) Multifamily Dwellings

For each dwelling unit of a multifamily dwelling where the dwelling unit is located at grade level and provided with individual exterior entrance/egress, at least one receptacle outlet readily accessible from grade and not more than 2.0 m (61/2 ft) above grade level shall be installed.

(3) Balconies, Decks, and Porches

Balconies, decks, and porches that are within 102 mm (4 in.) horizontally of the dwelling unit shall have at least one receptacle outlet accessible from the balcony, deck, or porch. The receptacle outlet shall not be located more than 2.0 m (61/2 ft) above the balcony, deck, or porch walking surface.

Related Code Sections


(E) Wiring and Protection, Outdoor Outlets
Outdoor receptacle outlets shall be installed in accordance with 210.52(E)(1) through (E)(3). Informational Note: See 210.8(A)(3 ...
National Electrical Code 2020 of Minnesota > 2 Wiring and Protection > 210 Branch Circuits > 210.52 Dwelling Unit Receptacle Outlets > (E) Outdoor Outlets
(E) Special Occupancies, Outdoor Receptacle Outlets
At least one receptacle outlet shall be installed outdoors. A receptacle outlet located in a compartment accessible from the outside of the park ...
National Electrical Code 2020 of Minnesota > 5 Special Occupancies > 552 Park Trailers > 552.41 Receptacle Outlets Required > (E) Outdoor Receptacle Outlets
(C) Special Occupancies, Outdoor Outlets, Luminaires, Air-Cooling Equipment, and So On
Outdoor luminaires and other equipment shall be listed for outdoor use ...
National Electrical Code 2020 of Minnesota > 5 Special Occupancies > 551 Recreational Vehicles and Recreational Vehicle Parks > 551.53 Luminaires and Other Equipment > (C) Outdoor Outlets, Luminaires, Air-Cooling Equipment, and So On
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING