• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2203.1.1 Outdoor Dispensing Devices

NYC Fire Code 2014 > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2203 Location of Liquid Motor Fuel-Dispensing Devices > 2203.1 Location of Dispensing Devices > 2203.1.1 Outdoor Dispensing Devices
JUMP TO FULL CODE CHAPTER
When installed outdoors, dispensing devices shall be located as follows:
  1. Ten feet (3048 mm) or more from lot lines and building or structure openings.
  2. Ten feet (3048 mm) or more from buildings or structures having combustible exterior wall surfaces or buildings or structures having noncombustible exterior wall surfaces that are not part of a 1-hour fire-resistance-rated assembly or buildings or structures having combustible overhangs.

    Exception: Canopies constructed in accordance with the construction codes, including the Building Code, providing weather protection for the motor fuel dispensers.
  3. Such that all portions of the vehicle being fueled will be on the premises of the motor fuel-dispensing facility.
  4. Such that the nozzle, when the hose is fully extended, will not reach within 5 feet (1524 mm) of building or structure openings.
  5. Twenty feet (6096 mm) or more from fixed sources of ignition.
  6. Twenty-five feet (7620 mm) or more from the nearest subway grating, entrance or exit.

Related Code Sections


414.6 Special Detailed Requirements Based on Use and Occupancy, Outdoor Storage, Dispensing and Use
The outdoor storage, dispensing and use of hazardous materials shall be in accordance with the New York City Fire Code ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use
414.6 Special Detailed Requirements Based on Use and Occupancy, Outdoor Storage, Dispensing and Use
The outdoor storage, dispensing and use of hazardous materials shall be in accordance with the New York City Fire Code ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use
414.6 Special Detailed Requirements Based on Use and Occupancy, Outdoor Storage, Dispensing and Use
The outdoor storage, dispensing and use of hazardous materials shall be in accordance with the New York City Fire Code ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 414 Hazardous Materials > 414.6 Outdoor Storage, Dispensing and Use
608.16.1 Water Supply and Distribution, Beverage Dispensers
The water supply connection to carbonated beverage dispensers shall be protected against backflow by a backflow preventer conforming to ASSE 1022 ...
NYC Plumbing Code 2008 > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.16 Connections to the Potable Water System > 608.16.1 Beverage Dispensers
608.16.1 Water Supply and Distribution, Beverage Dispensers
The water supply connection to beverage dispensers shall be protected against backflow by a backflow preventer conforming to ASSE 1022 or by an air ...
NYC Plumbing Code 2022 > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.16 Connections to the Potable Water System > 608.16.1 Beverage Dispensers
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING