923.0 Outdoor Cooking Appliances
JUMP TO FULL CODE CHAPTER
Listed outdoor cooking appliances shall be installed in accordance with their listing and the manufacturer's installation instructions.
Unlisted outdoor cooking appliances shall be installed outdoors with clearances to combustible material of not less than 36 inches (914 mm) at the sides and back and not less than 48 inches (1219 mm) at the front. In no case shall the appliance be located under overhead combustible construction. [NFPA 54:10.19.2]
Related Code Sections
923.0 Installation of Specific Appliances, Outdoor Cooking Appliances
Listed outdoor cooking appliances shall be installed in accordance with their listing and the manufacturer's installation instructions ...
Uniform Mechanical Code 2018 of Nevada > 9 Installation of Specific Appliances > 923.0 Outdoor Cooking Appliances
420.10.1 Special Detailed Requirements Based on Occupancy and Use, Cooking Appliances
Where located in Group R-2 college dormitories, domestic cooking appliances for use by residents shall be in compliance with all of the following ...
Building Code 2018 of Nevada > 4 Special Detailed Requirements Based on Occupancy and Use > 420 Groups I-1, R-1, R-2, R-3 and R-4 > 420.10 Group R-2 Dormitory Cooking Facilities > 420.10.1 Cooking Appliances
M1901.2 Special Appliances, Equipment and Systems, Cooking Appliances
Cooking appliances shall be listed and labeled for household use and shall be installed in accordance with the manufacturer's instructions. The ...
Residential Code 2012 of Nevada > 19 Special Appliances, Equipment and Systems > M1901 Ranges and Ovens > M1901.2 Cooking Appliances
M1901.2 Special Appliances, Equipment and Systems, Cooking Appliances
Cooking appliances shall be listed and labeled for household use and shall be installed in accordance with the manufacturer's instructions. The ...
Residential Code 2018 of Nevada > 19 Special Appliances, Equipment and Systems > M1901 Ranges and Ovens > M1901.2 Cooking Appliances
Section M1503 Exhaust Systems, Domestic Cooking Exhaust Equipment
for overhead range hoods and downdraft exhaust equipment not integral with the cooking appliance shall be listed and labeled in accordance with UL 507 ...