• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

715.3.2 Other Types of Doors

NYC Building Code 2008 > 7 Fire-Resistance-Rated Construction > 715 Opening Protectives > 715.3 Fire Door and Shutter Assemblies > 715.3.2 Other Types of Doors
JUMP TO FULL CODE CHAPTER
Other types of doors, including swinging elevator doors, shall be tested in accordance with NFPA 252 or UL 10B. The pressure in the furnace shall be maintained as nearly equal to the atmospheric pressure as possible. Once established, the pressure shall be maintained during the entire test period.

Related Code Sections


715.3.2 Fire-Resistance-Rated Construction, Other Types of Doors
Other types of doors, including swinging elevator doors, shall be tested in accordance with NFPA 252 or UL 10B. The pressure in the furnace shall ...
NYC Building Code 2008 > 7 Fire-Resistance-Rated Construction > 715 Opening Protectives > 715.3 Fire Door and Shutter Assemblies > 715.3.2 Other Types of Doors
715.4.2 Fire and Smoke Protection Features, Other Types of Assemblies
Fire door assemblies with other types of doors, including swinging elevator doors and fire shutter assemblies, shall be tested in accordance ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 715 Opening Protectives > 715.4 Fire Door and Shutter Assemblies > 715.4.2 Other Types of Assemblies
716.5.2 Fire and Smoke Protection Features, Other Types of Assemblies
Fire door assemblies with other types of doors, including swinging elevator doors, horizontal sliding fire door assemblies, and fire shutter ...
NYC Building Code 2022 > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.5 Fire Door and Shutter Assemblies > 716.5.2 Other Types of Assemblies
1010.1.7 Means of Egress, Thresholds
as required by Chapter 11. The door is not part of an Accessible unit, Type B+NYC unit or Type B unit. The exterior door, other than a storm or screen door ...
NYC Building Code 2022 > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.7 Thresholds
2.14.4.5.2 Electric Elevators,
of these doors is multisection and the other is single section, between the sections of the car door and the hoistway door nearest to each other (b ...
Safety Code for Elevators and Escalators 2013 of New York City > 2 Electric Elevators > 2.14 Car Enclosures, Car Doors and Gates, and Car Illumination > 2.14.4 Passenger and Freight Car Doors and Gates, General Requirements > 2.14.4.5 Location > 2.14.4.5.2
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING