• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

D102.2 Other Specific Requirements

NYC Building Code 2014 > D Fire Districts > D102 Building Restrictions > D102.2 Other Specific Requirements
JUMP TO FULL CODE CHAPTER

D102.2.1 Group H-1 Prohibited

Group H-1 occupancies shall be prohibited from location within the fire district.

D102.2.2 Construction Type

Every building, room, or space hereafter altered or erected shall be constructed as required based on the type of construction indicated in Chapter 6 except as provided in Section D102.2.4.

D102.2.3 Roof Covering

Roof covering in the fire district shall conform to the requirements of Class A or B roof coverings as defined in Section 1505.

D102.2.4 Structural Fire Rating

The fire-resistance rating of bearing walls, floors, roofs and their supporting structural members shall comply with Table 601 of Chapter 6, but in no event shall such rating be less than 1 hour.

Exceptions: The following buildings or building elements may be constructed with fire-resistance rating in accordance with Table 601:
  1. Buildings of Type IV construction.
  2. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.
  3. Automobile parking structures. Buildings surrounded on all sides by a permanently open space of not less than 30 feet (9144 mm).
  4. Partitions complying with Section 603.1, Item 11.

D102.2.5 R-1 and R-2 Occupancies

No building or space classified in Occupancy Group R-1 or R-2 may be located on a lot containing a building classified in construction Type IIB, VA or VB.

Related Code Sections


D102.2 Fire Districts, Other Specific Requirements
Every building, room, or space hereafter altered or erected shall be constructed as required based on the type ...
NYC Building Code 2014 > D Fire Districts > D102 Building Restrictions > D102.2 Other Specific Requirements
D102.2 Fire Districts, Other Specific Requirements
Every building, room, or space hereafter altered or erected shall be constructed as required based on the type ...
NYC Building Code 2008 > D Fire Districts > D102 Building Restrictions > D102.2 Other Specific Requirements
D102.2 Fire Districts, Other Specific Requirements
Every building, room, or space hereafter altered or erected shall be constructed as required based on the type ...
NYC Building Code 2022 > D Fire Districts > D102 Building Restrictions > D102.2 Other Specific Requirements
D102.2.2 Fire Districts, Construction Type
Every building, room, or space hereafter altered or erected shall be constructed as required based on the type of construction indicated in Chapter 6 ...
NYC Building Code 2022 > D Fire Districts > D102 Building Restrictions > D102.2 Other Specific Requirements > D102.2.2 Construction Type
D102.2.3 Fire Districts, Roof Covering
Roof covering in the fire district shall conform to the requirements of Class A or B roof coverings as defined in Section 1505 ...
NYC Building Code 2014 > D Fire Districts > D102 Building Restrictions > D102.2 Other Specific Requirements > D102.2.3 Roof Covering
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING