1910.179(o) Other Requirements, General—
JUMP TO FULL CODE CHAPTER
The employer shall insure that hands are free from encumbrances while personnel are using ladders.
Articles which are too large to be carried in pockets or belts shall be lifted and lowered by hand line.
Necessary clothing and personal belongings shall be stored in such a manner as not to interfere with access or operation.
Tools, oil cans, waste, extra fuses, and other necessary articles shall be stored in the tool box, and shall not be permitted to lie loose in or about the cab.
The employer shall insure that operators are familiar with the operation and care of fire extinguishers provided.
[39 FR 23502, June 27, 1974, as amended at 40 FR 27400, June 27, 1975; 49 FR 5322, Feb. 10, 1984; 51 FR 34560, Sept. 29, 1986; 55 FR 32015, Aug. 6, 1990; 61 FR 9227, March 7, 1996; 81 83005, Nov. 18, 2016]
[39 FR 23502, June 27, 1974, as amended at 40 FR 27400, June 27, 1975; 49 FR 5322, Feb. 10, 1984; 51 FR 34560, Sept. 29, 1986; 55 FR 32015, Aug. 6, 1990; 61 FR 9227, March 7, 1996; 81 83005, Nov. 18, 2016]
Related Code Sections
1910.179(o) Materials Handling and Storage, Other Requirements, General—
, extra fuses, and other necessary articles shall be stored in the tool box, and shall not be permitted to lie loose in or about the cab ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.179 Overhead and Gantry Cranes > 1910.179(o) Other Requirements, General—
1910.179(o)(1)(ii) Materials Handling and Storage,
Articles which are too large to be carried in pockets or belts shall be lifted and lowered by hand line ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.179 Overhead and Gantry Cranes > 1910.179(o) Other Requirements, General— > 1910.179(o)(1) Ladders > 1910.179(o)(1)(ii)
1910.179(o)(2)(i) Materials Handling and Storage,
Necessary clothing and personal belongings shall be stored in such a manner as not to interfere with access or operation ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.179 Overhead and Gantry Cranes > 1910.179(o) Other Requirements, General— > 1910.179(o)(2) Cabs > 1910.179(o)(2)(i)
1910.261(a)(4)(i) Special Industries,
ASME Boiler and Pressure Vessel Code, Section VIII, Unfired Pressure Vessels, including addenda 1969 ...
OSHA 1910 General Industry > R Special Industries > 1910.261 Pulp, Paper, and Paperboard Mills > 1910.261(a) General Requirements > 1910.261(a)(4) Other Standards > 1910.261(a)(4)(i)
1910.261(a)(4)(ii) Special Industries,
Building Exits Code for Life Safety from Fire, NFPA 101—1970 ...
OSHA 1910 General Industry > R Special Industries > 1910.261 Pulp, Paper, and Paperboard Mills > 1910.261(a) General Requirements > 1910.261(a)(4) Other Standards > 1910.261(a)(4)(ii)