• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(vi) 903.2.11.6 Other Required Suppression System

Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-09 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Buildings Areas and Hazards > 903.2.11.6 Other Required Suppression System
JUMP TO FULL CODE CHAPTER
In addition to the requirements of paragraph (C)(2)(903.2) of this rule, the provisions indicated in Table 903.2.11.6 of this rule also require the installation of a fire suppression system for certain buildings and areas.

TABLE 903.2.11.6
ADDITIONAL REQUIRED FIRE EXTINGUISHING SYSTEMS
SECTIONSUBJECT
914.2.1Covered malls
914.3.1High rise buildings
914.4.1Atriums
914.5.1Underground structures
914.6.1Stages
914.7.1Special amusement buildings
914.8.2, 914.8.5Aircraft hangars
914.9Flammable finishes
914.10Drying rooms
914.11.1Group B ambulatory heatlh care facilities
1024.6.2.3Smoke-protected seating
1208.2Dry cleaning plants
1208.3Dry cleaning machines
1504.2Spray finishing in Group A, E, I or R
1504.4Spray booths and spray rooms
1505.2Dip-tank rooms in Group A, I or R
1505.4.1Dip tanks
1505.9.4Hardening and tempering tanks
1803.10HPM facilities
1803.10.1.1HPM work station exhaust
1803.10.2HPM gas cabinets and exhausted enclosures
1803.10.3HPM exit access corridor
1803.10.4HPM exhaust ducts
1803.10.4.1HPM noncombustible ducts
1803.10.4.2HPM combustible ducts
1907.3Lumber production conveyor enclosures
1908.7Recycling facility conveyor enclosures
2106.1Class A and B ovens
2106.2Class C and D ovens
2209.3.2.6.2Hydrogen motor fuel-dispensing area canopies
Table 2306.2Storage fire protection
2306.4Storage
2703.8.4.1Gas rooms
2703.8.5.3Exhausted enclosures
2704.5Indoor storage of hazardous materials
2705.1.8Indoor dispensing of hazardous materials
2804.4.1Aerosol warehouses
2806.3.2Aerosol display and merchandising areas
2904.5Storage of more than 1,000 cubic feet of loose
combustible fibers
3306.5.2.1Storage of smokeless propellant
3306.5.2.3Storage of small arms primers
3404.3.7.5.1Flammable and combustible liquid storage rooms
3404.3.8.4Flammable and combustible liquid storage
warehouses
3405.3.7.3Flammable and combustible liquid Group H-2 or
H-3 areas
3704.1.2Gas cabinets for highly toxic and toxic gas
3704.1.3Exhausted enclosures for highly toxic and toxic gas
3704.2.2.6Gas rooms for highly toxic and toxic gas
3704.3.3Outdoor storage for highly toxic and toxic gas
4204.1.1Pyroxylin plastic storage cabinets
4204.1.3Pyroxylin plastic storage vaults
4204.2Pyroxylin plastic storage and manufacturing
4603.4.1Pyroxylin plastic storage in existing buildings
4603.4.2Existing Group I-2 occupancies
The building
code as listed
in rule 1301:7-7-47 of the Administrative Code
Sprinkler system requirements as set forth in section 903.2.11.6 of the building code as listed in rule 1301:7-7-47 of the Administrative Code
For SI: 1 cubic foot = 0.023 m3.

Related Code Sections


903.2.11.6 Fire Protection Systems, Other Required Suppression Systems
In addition to the requirements of Section 903.2, the provisions indicated in Table 903.2.11.6 require the installation of a fire suppression system ...
Ohio Building Code 2017 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.6 Other Required Suppression Systems
903.2.11.6 Ohio Administrative Code 1301:7-7-09 Fire Protection Systems, Other Required Suppression System
the installation of a fire suppression system for certain buildings and areas. TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE EXTINGUISHING ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-09 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Buildings Areas and Hazards > 903.2.11.6 Other Required Suppression System
903.2.11.6 Ohio Administrative Code 1301:7-7-09 Fire Protection Systems, Other Required Suppression System
the installation of a fire suppression system for certain buildings and areas. TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE EXTINGUISHING SYSTEMS ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-09 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Buildings Areas and Hazards > 903.2.11.6 Other Required Suppression System
903.2.11.6 Fire Protection Systems, Other Required Suppression Systems
system for certain buildings and areas. TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS SECTION SUBJECT 402.9 Covered malls ...
Ohio Building Code 2011 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.6 Other Required Suppression Systems
14.2.6 Inspection, Testing, and Maintenance, Releasing Systems
Requirements pertinent to testing the fire alarm systems initiating fire suppression system releasing functions shall be covered by 14.2.6.1 through ...
National Fire Alarm and Signaling Code 2016 of Ohio > 14 Inspection, Testing, and Maintenance > 14.2 General > 14.2.6 Releasing Systems
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING