// CODE SNIPPET
903.2.13 Other Required Fire Extinguishing Systems
JUMP TO FULL CODE CHAPTER
In addition to the requirements of FC903.2, the provisions indicated in FC Table 903.2.13 also require the installation of a fire extinguishing system for certain buildings and areas.
FC TABLE 903.2.13 ADDITIONAL REQUIRED FIRE EXTINGUISHING SYSTEMS
FC TABLE 903.2.13 ADDITIONAL REQUIRED FIRE EXTINGUISHING SYSTEMS
SECTION | SUBJECT |
1208.2 | Dry cleaning facilities |
1208.3 | Dry cleaning machines |
1504.3.3.1 | Spray rooms |
1504.3.3.2 | Spray booths |
1505.2 | Dip-tank rooms |
1505.3.4.2 | Dip tanks |
1505.4.4 | Hardening and tempering tanks |
1803.10 | HPM facilities |
1803.10.1.1 | HPM work station exhaust |
1803.10.2 | HPM gas cabinets |
1803.10.3 | HPM corridors |
1803.10.4 | HPM exhaust |
1803.10.4.1 | HPM noncombustible ducts |
1803.10.4.2 | HPM combustible ducts |
2106.1 | Class A and B furnaces |
2106.2 | Class C and D furnaces |
2206.8 | Flammable liquid motor fuel-dispensing areas |
2208.7.4 | Indoor CNG compressing, storage and dispensing areas |
2209.3.4.2 | Hydrogen motor fuel-dispensing areas under canopies |
FC Table 2306.2 | High-piled storage fire protection |
2306.4 | High-piled storage |
2703.8.4.1 | Gas rooms |
2703.8.5.3 | Exhausted enclosures |
2704.5 | Indoor storage of hazardous materials |
2705.1.8 | Indoor handling and use of hazardous materials |
2804.4.1 | Aerosol warehouses |
2904.5 | Storage of more than 1,000 cubic feet of loose com- bustible fibers |
3306.7 | Storage of small arm ammunition, powder-actuated tool loads, black powder or smokeless propellant |
3404.3.7.5.1 | Flammable and combustible liquid storage rooms |
3404.3.8.4 | Flammable and combustible liquid storage warehouses |
3405.3.7.3 | Flammable and combustible liquid Group H-2 or H-3 areas |
3704.1.2.2 | Gas cabinets for highly toxic and toxic gas |
3704.1.3.1 | Exhausted enclosures for highly toxic and toxic gas |
3704.2.2.6 | Gas rooms for highly toxic and toxic gas |
3704.3.3 | Outdoor storage for highly toxic and toxic gas |
4204.1.1 | Pyroxylin plastic storage cabinets and vaults |
4204.1.3 | Pyroxylin plastic storage vaults |
4204.2 | Pyroxylin plastic storage, handling and use |
Building Code | Sprinkler requirements as set forth in the construc- tion codes, including the Building Code |
For SI: 1 cubic foot = 0.023 m3.
Related Code Sections
904.2 Fire Protection Systems, Where Required
by other requirements of this code. Exception: Automatic fire-extinguishing systems installed in Group H occupancies as an alternative ...
NYC Building Code 2008 > 9 Fire Protection Systems > 904 Alternative Automatic Fire-Extinguishing Systems > 904.2 Where Required
*904.2 Fire Protection Systems, Where Required
Automatic fire-extinguishing systems installed as an alternative
to the required automatic sprinkler systems of Section 903 shall be approved ...
NYC Building Code 2014 > 9 Fire Protection Systems > 904 Alternative Automatic Fire-Extinguishing Systems > *904.2 Where Required
*904.2 Fire Protection Systems, Where Required
Automatic fire-extinguishing systems installed as an alternative
to the required automatic sprinkler systems of Section 903 shall be approved ...
NYC Building Code 2022 > 9 Fire Protection Systems > 904 Alternative Automatic Fire-Extinguishing Systems > *904.2 Where Required
904.3.3 Fire Protection Systems, System Interlocking
and other features necessary for proper operation of the fire-extinguishing system shall be provided as required by the design and installation standard ...
NYC Building Code 2022 > 9 Fire Protection Systems > 904 Alternative Automatic Fire-Extinguishing Systems > 904.3 Installation > 904.3.3 System Interlocking
§27-780 Mechanical Ventilation, Air Conditioning, and Refrigeration Systems, Voluntary Ventilating Systems or Other Voluntary Air Duct Systems
or other air duct system when smoke detectors or fire protection devices are required. (a) Procedure. A voluntary ventilating system or other ...
NYC 1968 Code (Vol I) > 13 Mechanical Ventilation, Air Conditioning, and Refrigeration Systems > 2 Inspections and Tests for Equipment Use Permits > §27-780 Voluntary Ventilating Systems or Other Voluntary Air Duct Systems