• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1005.7.2 Other Projections

Building Code 2018 of Illinois > 10 Means of Egress > 1005 Means of Egress Sizing > 1005.7 Encroachment > 1005.7.2 Other Projections
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Handrail projections shall be in accordance with the provisions of Section 1014.8. Other nonstructural projections such as trim and similar decorative features shall be permitted to project into the required width not more than 11/2 inches (38 mm) on each side.
Exception: Projections are permitted in corridors within Group I-2 Condition 1 in accordance with Section 407.4.3.

Related Code Sections


1005.7.2 Means of Egress, Other Projections
Handrail projections shall be in accordance with the provisions of Section 1014.8. Other nonstructural projections such as trim and similar ...
Building Code 2018 of Illinois > 10 Means of Egress > 1005 Means of Egress Sizing > 1005.7 Encroachment > 1005.7.2 Other Projections
1005.7.2 Means of Egress, Other Projections
Handrail projections shall be in accordance with the provisions of Section 1014.8. Other nonstructural projections such as trim and similar ...
Building Code 2021 of Illinois > 10 Means of Egress > 1005 Means of Egress Sizing > 1005.7 Encroachment > 1005.7.2 Other Projections
19.3.4 Concrete: Design and Durability Requirements, Additional Requirements for Chloride Ion Content
C1 unless a more stringent limit is required by other project conditions ...
Building Code Requirements for Structural Concrete of Illinois > 19 Concrete: Design and Durability Requirements > 19.3 Concrete Durability Requirements > 19.3.4 Additional Requirements for Chloride Ion Content
2510.5.1 Gypsum Board, Gypsum Panel Products and Plaster, Support of Lath
Where lath on vertical surfaces extends between rafters or other similar projecting members, solid backing shall be installed to provide support ...
Building Code 2021 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2510 Lathing and Furring for Cement Plaster (Stucco) > 2510.5 Backing > 2510.5.1 Support of Lath
2510.5.1 Gypsum Board, Gypsum Panel Products and Plaster, Support of Lath
Where lath on vertical surfaces extends between rafters or other similar projecting members, solid backing shall be installed to provide support ...
Building Code 2018 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2510 Lathing and Furring for Cement Plaster (Stucco) > 2510.5 Backing > 2510.5.1 Support of Lath
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING