// CODE SNIPPET
1910.243(c)(4) Other Portable Grinders
JUMP TO FULL CODE CHAPTER
The maximum angular exposure of the grinding wheel periphery and sides for safety guards used on other portable grinding machines shall not exceed 180 deg. and the top half of the wheel shall be enclosed at all times. (See Figures P-5 and P-6.)
Figure No. P-5
Figure No. P-6


Related Code Sections
1910.243(c)(4) Hand and Portable Powered Tools and Other Hand-Held Equipment, Other Portable Grinders
The maximum angular exposure of the grinding wheel periphery and sides for safety guards used on other portable grinding machines shall not exceed ...
OSHA 1910 General Industry > P Hand and Portable Powered Tools and Other Hand-Held Equipment > 1910.243 Guarding of Portable Powered Tools > 1910.243(c) Portable Abrasive Wheels > 1910.243(c)(4) Other Portable Grinders
1910.94(b)(1)(xiv) Occupational Health and Environmental Control, Portable Grinder
Any power-driven rotatable grinding, polishing, or buffing wheel mounted in such manner that it may be manually manipulated ...
OSHA 1910 General Industry > G Occupational Health and Environmental Control > 1910.94 Ventilation > 1910.94(b) Grinding, Polishing, and Buffing Operations > 1910.94(b)(1) Definitions Applicable to This Paragraph > 1910.94(b)(1)(xiv) Portable Grinder
1910.215(b)(4) Machinery and Machine Guarding, Cylindrical Grinders
The maximum angular exposure of the grinding wheel periphery and sides for safety guards used on cylindrical grinding machines shall not exceed 180 ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.215 Abrasive Wheel Machinery > 1910.215(b) Guarding of Abrasive Wheel Machinery > 1910.215(b)(4) Cylindrical Grinders
1910.261(i)(1) Special Industries, Pulp Grinders
Water wheels directly connected to pulp grinders shall be provided with speed governors limiting the peripheral speed of the grinder ...
OSHA 1910 General Industry > R Special Industries > 1910.261 Pulp, Paper, and Paperboard Mills > 1910.261(i) Mechanical Pulp Process > 1910.261(i)(1) Pulp Grinders
1910.215(b)(6) Machinery and Machine Guarding, Swing Frame Grinders
The maximum angular exposure of the grinding wheel periphery and sides for safety guards used on machines known as swing frame grinding machines shall ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.215 Abrasive Wheel Machinery > 1910.215(b) Guarding of Abrasive Wheel Machinery > 1910.215(b)(6) Swing Frame Grinders