• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3203.10.3 Other Pallets

Fire Code 2018 of Colorado > 32 High-Piled Combustible Storage > 3203 Commodity Classification > 3203.10 Plastic Pallets > 3203.10.3 Other Pallets
JUMP TO FULL CODE CHAPTER
For Class I through IV commodities stored on plastic pallets other than polypropylene or high-density polyethylene plastic pallets, the commodity classification shall be increased two classes unless specific testing is conducted by a testing laboratory.

Related Code Sections


3203.10.3 High-Piled Combustible Storage, Other Pallets
For Class I through IV commodities stored on plastic pallets other than polypropylene or high-density polyethylene plastic pallets, the commodity ...
Fire Code 2021 of Colorado > 32 High-Piled Combustible Storage > 3203 Commodity Classification > 3203.10 Plastic Pallets > 3203.10.3 Other Pallets
3203.10.3 High-Piled Combustible Storage, Other Pallets
For Class I through IV commodities stored on plastic pallets other than polypropylene or high-density polyethylene plastic pallets, the commodity ...
Fire Code 2018 of Colorado > 32 High-Piled Combustible Storage > 3203 Commodity Classification > 3203.10 Plastic Pallets > 3203.10.3 Other Pallets
315.7.6.2 General Requirements, Separation From Other Pallets and On-Site Storage
Pallets shall be separated from other pallet piles and other storage in accordance with Table 315.7.6(3) for wood pallets and Table 315.7.6(4 ...
Fire Code 2021 of Colorado > 3 General Requirements > 315 General Storage > 315.7 Outdoor Pallet Storage > 315.7.6 Pile Separation Distances > 315.7.6.2 Separation From Other Pallets and On-Site Storage
315.7.6.2 General Requirements, Separation From Other Pallets and On-Site Storage
Pallets shall be separated from other pallet piles and other storage in accordance with Table 315.7.6(3) for wood pallets and Table 315.7.6(4 ...
Fire Code 2018 of Colorado > 3 General Requirements > 315 General Storage > 315.7 Outdoor Pallet Storage > 315.7.6 Pile Separation Distances > 315.7.6.2 Separation From Other Pallets and On-Site Storage
12.12.2.2.4.3 General Requirements for Storage,
m). Sprinkler protection shall employ high temperature-rated sprinklers. Each pallet pile of no more than two stacks shall be separated from other ...
Standard for the Installation of Sprinkler Systems 2013 of Colorado > 12 General Requirements for Storage > 12.12* Protection of Idle Pallets > 12.12.2 Plastic Pallets > 12.12.2.2 Protection Criteria for Plastic Pallets Stored Indoors > 12.12.2.2.4 > 12.12.2.2.4.3
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING