• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E3901.3.1 Other Outlets Prohibited

Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3901 Receptacle Outlets > E3901.3 Small Appliance Receptacles > E3901.3.1 Other Outlets Prohibited
JUMP TO FULL CODE CHAPTER
The two or more small-appliance branch circuits specified in Section E3901.3 shall serve no other outlets. [210.52(B)(2)]
Exceptions:
  1. A receptacle installed solely for the electrical supply to and support of an electric clock in any of the rooms specified in Section E3901.3. [210.52(B)(2) Exception No.1]
  2. Receptacles installed to provide power for supplemental equipment and lighting on gas-fired ranges, ovens, and counter-mounted cooking units. [210.52(B)(2) Exception No. 2]

Related Code Sections


E3901.3.1 Power and Lighting Distribution, Other Outlets Prohibited
The two or more small-appliance branch circuits specified in Section E3901.3 shall serve no other outlets. [210.52(B)(2)] Exceptions: A ...
Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3901 Receptacle Outlets > E3901.3 Small Appliance Receptacles > E3901.3.1 Other Outlets Prohibited
618.3 Specific Appliances, Prohibited Sources
) from an appliance vent outlet, a vent opening from a plumbing drainage system or the discharge outlet of an exhaust fan, unless the outlet is 3 feet ...
Fuel Gas Code 2018 of Kansas > 6 Specific Appliances > 618 (IFGC) Forced-Air Warm-Air Furnaces > 618.3 Prohibited Sources
406.5.11 Special Detailed Requirements Based on Occupancy and Use, Prohibitions
closing of required openings in exterior walls by tarpaulins or any other means. Dispensing of fuel ...
Building Code 2018 of Kansas > 4 Special Detailed Requirements Based on Occupancy and Use > 406 Motor-Vehicle-Related Occupancies > 406.5 Open Parking Garages > 406.5.11 Prohibitions
1402.5 Solar Thermal Systems, Protection of Potable Water
heating system. This requirement shall not prohibit the presence of inlets or outlets on the solar heating loop for the purposes of servicing the fluid ...
Mechanical Code 2018 of Kansas > 14 Solar Thermal Systems > 1402 Design and Installation > 1402.5 Protection of Potable Water
(L) Wiring and Protection, Other Outlets
Other outlets not covered in 220.14(A) through (K) shall be calculated based on 180 volt-amperes per outlet ...
National Electrical Code 2017 of Kansas > 2 Wiring and Protection > 220 Branch-Circuit, Feeder, and Service Load Calculations > 220.14 Other Loads — All Occupancies > (L) Other Outlets
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING