• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(L) Other Outlets

National Electrical Code 2020 of Illinois > 2 Wiring and Protection > 220 Branch-Circuit, Feeder, and Service Load Calculations > 220.14 Other Loads — All Occupancies > (L) Other Outlets
JUMP TO FULL CODE CHAPTER
Other outlets not covered in 220.14(A) through (K) shall be calculated based on 180 volt-amperes per outlet.

Related Code Sections


(L) Wiring and Protection, Other Outlets
Other outlets not covered in 220.14(A) through (K) shall be calculated based on 180 volt-amperes per outlet ...
National Electrical Code 2017 of Illinois > 2 Wiring and Protection > 220 Branch-Circuit, Feeder, and Service Load Calculations > 220.14 Other Loads — All Occupancies > (L) Other Outlets
(L) Wiring and Protection, Other Outlets
Other outlets not covered in 220.14(A) through (K) shall be calculated based on 180 volt-amperes per outlet ...
National Electrical Code 2020 of Illinois > 2 Wiring and Protection > 220 Branch-Circuit, Feeder, and Service Load Calculations > 220.14 Other Loads — All Occupancies > (L) Other Outlets
(D) Special Equipment, Other Outlets
Other outlets shall be not less than 3.0 m (10 ft) from the inside walls of the pool. Measurements shall be determined in accordance with 680.22(A)(6 ...
National Electrical Code 2020 of Illinois > 6 Special Equipment > 680 Swimming Pools, Fountains, and Similar Installations > 680.22 Lighting, Receptacles, and Equipment > (D) Other Outlets
(D) Special Equipment, Other Outlets
Other outlets shall be not less than 3.0 m (10 ft) from the inside walls of the pool. Measurements shall be determined in accordance with 680.22(A)(5 ...
National Electrical Code 2017 of Illinois > 6 Special Equipment > 680 Swimming Pools, Fountains, and Similar Installations > 680.22 Lighting, Receptacles, and Equipment > (D) Other Outlets
(2) Wiring and Protection, No Other Outlets
The two or more small-appliance branch circuits specified in 210.52(B)(1) shall have no other outlets. Exception No. 1: A receptacle installed ...
National Electrical Code 2017 of Illinois > 2 Wiring and Protection > 210 Branch Circuits > 210.52 Dwelling Unit Receptacle Outlets > (B) Small Appliances > (2) No Other Outlets
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING