• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1605.2.1 Other Loads

Building Code 2018 of Illinois > 16 Structural Design > 1605 Load Combinations > 1605.2 Load Combinations Using Strength Design or Load and Resistance Factor Design > 1605.2.1 Other Loads
JUMP TO FULL CODE CHAPTER
Where flood loads, Fa, are to be considered in the design, the load combinations of Section 2.3.2 of ASCE 7 shall be used. Where self-straining loads, T, are considered in design, their structural effects in combination with other loads shall be determined in accordance with Section 2.3.4 of ASCE 7. Where an ice-sensitive structure is subjected to loads due to atmospheric icing, the load combinations of Section 2.3.3 of ASCE 7 shall be considered.

Related Code Sections


1605.2.1 Structural Design, Other Loads
loads, T, are considered in design, their structural effects in combination with other loads shall be determined in accordance with Section 2.3.4 ...
Building Code 2018 of Illinois > 16 Structural Design > 1605 Load Combinations > 1605.2 Load Combinations Using Strength Design or Load and Resistance Factor Design > 1605.2.1 Other Loads
(4) Wiring and Protection, Other Loads
Branch-circuit conductors that supply loads other than those specified in 210.3 and other than cooking appliances as covered in 210.19(A)(3) shall ...
National Electrical Code 2017 of Illinois > 2 Wiring and Protection > 210 Branch Circuits > 210.19 Conductors — Minimum Ampacity and Size > (A) Branch Circuits Not More Than 600 Volts > (4) Other Loads
(4) Wiring and Protection, Other Loads
Branch-circuit conductors that supply loads other than those specified in 210.3 and other than cooking appliances as covered in 210.19(A)(3) shall ...
National Electrical Code 2020 of Illinois > 2 Wiring and Protection > 210 Branch Circuits > 210.19 Conductors — Minimum Ampacity and Size > (A) Branch Circuits Not More Than 600 Volts > (4) Other Loads
(F) Special Equipment, Other Loads
Additional loads, such as heating, lighting, and air conditioning, shall be provided for by application of the appropriate sections of this Code ...
National Electrical Code 2017 of Illinois > 6 Special Equipment > 610 Cranes and Hoists > 610.14 Rating and Size of Conductors > (F) Other Loads
(F) Special Equipment, Other Loads
Additional loads, such as heating, lighting, and air conditioning, shall be provided for by application of the appropriate sections of this Code ...
National Electrical Code 2020 of Illinois > 6 Special Equipment > 610 Cranes and Hoists > 610.14 Rating and Size of Conductors > (F) Other Loads
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING