• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R702.5 Other Finishes

Residential Code 2018 of Kansas > 7 Wall Covering > R702 Interior Covering > R702.5 Other Finishes
JUMP TO FULL CODE CHAPTER
Wood veneer paneling and hardboard paneling shall be placed on wood or cold-formed steel framing spaced not more than 16 inches (406 mm) on center. Wood veneer and hard board paneling less than 1/4-inch (6 mm) nominal thickness shall not have less than a 3/8-inch (10 mm) gypsum board or gypsum panel product backer. Wood veneer paneling not less than 1/4-inch (6 mm) nominal thickness shall conform to ANSI/HPVA HP-1. Hardboard paneling shall conform to CPA/ANSI A135.5.

Related Code Sections


R702.5 Wall Covering, Other Finishes
Wood veneer paneling and hardboard paneling shall be placed on wood or cold-formed steel framing spaced not more than 16 inches (406 mm) on center ...
Residential Code 2018 of Kansas > 7 Wall Covering > R702 Interior Covering > R702.5 Other Finishes
(B) Equipment for General Use, Secured in Place
Cables shall be secured in place by nonmetallic frames or spreaders or other approved means while the concrete or other finish is applied ...
National Electrical Code 2017 of Kansas > 4 Equipment for General Use > 424 Fixed Electric Space-Heating Equipment > 424.44 Installation of Cables in Concrete or Poured Masonry Floors > (B) Secured in Place
(1) Equipment for General Use, Non-Type IC
combustible materials. The points of support and the trim finishing off the openings in the ceiling, wall, or other finished surface shall be permitted ...
National Electrical Code 2017 of Kansas > 4 Equipment for General Use > 410 Luminaires, Lampholders, and Lamps > 410.116 Clearance and Installation > (A) Clearance > (1) Non-Type IC
R608.4.3 Wall Construction, Exterior Wall Covering
Requirements for installation of masonry veneer, stucco and other finishes on the exterior of concrete walls and other construction details ...
Residential Code 2018 of Kansas > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.4 Stay-In-Place Forms > R608.4.3 Exterior Wall Covering
E4004.8 Devices and Luminaires, Recessed Luminaire Clearance
combustible materials. The points of support and the finish trim parts at the opening in the ceiling, wall or other finished surface shall be permitted ...
Residential Code 2018 of Kansas > 40 Devices and Luminaires > E4004 Luminaire Installation > E4004.8 Recessed Luminaire Clearance
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING