807.5.3.4 Other Areas in Groups I-2, I-1.2 and R-2.1
JUMP TO FULL CODE CHAPTER
In Group I-2, I-1.2 and R-2.1 occupancies, in areas not equipped throughout with an approved automatic sprinkler system, combustible decorative materials shall be of such limited quantities that a hazard of fire development or spread is not present.
Related Code Sections
807.5.3.4 Interior Finish, Decorative Materials and Furnishings, Other Areas in Groups I-2, I-1.2 and R-2.1
In Group I-2, I-1.2 and R-2.1 occupancies, in areas not equipped throughout with an approved automatic sprinkler system, combustible decorative ...
California Fire Code 2016 > 8 Interior Finish, Decorative Materials and Furnishings > 807 Decorative Materials Other Than Decorative Vegetation in New and Existing Buildings > 807.5 Occupancy-Based Requirements > 807.5.3 Groups I-2, I-1.2 and R-2.1 > 807.5.3.4 Other Areas in Groups I-2, I-1.2 and R-2.1
807.5.3.4 Interior Finish, Decorative Materials and Furnishings, Other Areas in Groups I-2, I-1.2 and R-2.1
In Group I-2, I-1.2 and R-2.1 occupancies, in areas not equipped throughout with an approved automatic sprinkler system, combustible decorative ...
California Fire Code 2019 > 8 Interior Finish, Decorative Materials and Furnishings > 807 Decorative Materials and Artificial Decorative Vegetation in New and Existing Buildings > 807.5 Occupancy-Based Requirements > 807.5.3 Groups I-2, I-1.2 and R-2.1 > 807.5.3.4 Other Areas in Groups I-2, I-1.2 and R-2.1
508.2.4 General Building Heights and Areas, Separation of Occupancies
shall be separated from all other occupancies in accordance with Section 508.4. Group R-1, R-2, R-2.1, R-2.2 and R-3 dwelling units and sleeping ...
California Building Code 2019 (Vol 1 & 2) > 5 General Building Heights and Areas > 508 Mixed Use and Occupancy > 508.2 Accessory Occupancies > 508.2.4 Separation of Occupancies
508.2.4 General Building Heights and Areas, Separation of Occupancies
be separated from all other occupancies in accordance with Section 508.4. Group I-1, R-1, R-2, R-2.1 and R-3 dwelling units and sleeping units ...
California Building Code 2016 (Vol 1 & 2) > 5 General Building Heights and Areas > 508 Mixed Use and Occupancy > 508.2 Accessory Occupancies > 508.2.4 Separation of Occupancies
807.5.3.3 Interior Finish, Decorative Materials and Furnishings, In Group I-2 and I-2.1
In Group I-2 occupancies equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1, combustible ...
California Fire Code 2019 > 8 Interior Finish, Decorative Materials and Furnishings > 807 Decorative Materials and Artificial Decorative Vegetation in New and Existing Buildings > 807.5 Occupancy-Based Requirements > 807.5.3 Groups I-2, I-1.2 and R-2.1 > 807.5.3.3 In Group I-2 and I-2.1