Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(I) Other Applications

National Electrical Code 2020 of Minnesota > 7 Special Conditions > 725 Class 1, Class 2, and Class 3 Remote- Control, Signaling, and Power-Limited Circuits > 725.136 Separation From Electric Light, Power, Class 1, Non- Power-Limited Fire Alarm Circuit Conductors, and Medium- Power Network-Powered Broadband Communications Cables > (I) Other Applications
JUMP TO FULL CODE CHAPTER
For other applications, conductors of Class 2 and Class 3 circuits shall be separated by at least 50 mm (2 in.) from conductors of any electric light, power, Class 1 non-power-limited fire alarm or medium power network-powered broadband communications circuits unless one of the following conditions is met:
  1. Either all of the electric light, power, Class 1, non-powerlimited fire alarm and medium-power network-powered broadband communications circuit conductors or all of the Class 2 and Class 3 circuit conductors are in a raceway or in metal-sheathed, metal-clad, nonmetallic-sheathed, Type TC, or Type UF cables
  2. All of the electric light, power, Class 1 non-power-limited fire alarm, and medium-power network-powered broadband communications circuit conductors are permanently separated from all of the Class 2 and Class 3 circuit conductors by a continuous and firmly fixed nonconductor, such as porcelain tubes or flexible tubing, in addition to the insulation on the conductors

Related Code Sections


17.6.3.7 Initiating Devices, Other Applications
Where a detector is used in an application other than open area protection, the manufacturer's published instructions shall be followed ...
National Fire Alarm and Signaling Code 2016 of Minnesota > 17 Initiating Devices > 17.6 Heat-Sensing Fire Detectors > 17.6.3 Location and Spacing > 17.6.3.7 Other Applications
5703.1.3 Flammable and Combustible Liquids, Other Applications
The fire code official is authorized to determine the extent of the Class I electrical equipment and wiring location when a condition ...
Minnesota Fire Code 2015 > 57 Flammable and Combustible Liquids > 5703 General Requirements > 5703.1 Electrical > 5703.1.3 Other Applications
5703.1.3 Flammable and Combustible Liquids, Other Applications
The fire code official is authorized to determine the extent of the Class I electrical equipment and wiring location where a condition ...
2020 Minnesota State Fire Code > 57 Flammable and Combustible Liquids > 5703 General Requirements > 5703.1 Electrical > 5703.1.3 Other Applications
(I) Special Conditions, Other Applications
For other applications, conductors of Class 2 and Class 3 circuits shall be separated by at least 50 mm (2 in.) from conductors of any electric light ...
National Electrical Code 2020 of Minnesota > 7 Special Conditions > 725 Class 1, Class 2, and Class 3 Remote- Control, Signaling, and Power-Limited Circuits > 725.136 Separation From Electric Light, Power, Class 1, Non- Power-Limited Fire Alarm Circuit Conductors, and Medium- Power Network-Powered Broadband Communications Cables > (I) Other Applications
(G) Special Conditions, Other Applications
For other applications, power-limited fire alarm circuit conductors shall be separated by at least 50 mm (2 in.) from conductors of any electric ...
National Electrical Code 2020 of Minnesota > 7 Special Conditions > 760 Fire Alarm Systems > 760.136 Separation From Electric Light, Power, Class 1, NPLFA, and Medium-Power Network-Powered Broadband Communications Circuit Conductors > (G) Other Applications
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING