903.2.11.2 Other Above-Grade Stories
JUMP TO FULL CODE CHAPTER
An automatic sprinkler system shall be installed throughout every above-grade story of buildings below a height of 100 feet (30 480 mm), other than the first story or ground floor, on which access is not provided directly from the outdoors by at least one window or readily identifiable access panel within each 50 feet (15 240 mm) or fraction thereof of horizontal length of every wall that fronts on a street or frontage space required pursuant to Section 501.3.1.
Such windows shall be openable from the inside or breakable from both the inside and the outside, and shall have a size when open of at least 24 inches by 36 inches (610 mm by 914 mm). Such panels shall be openable from both the inside and outside and shall have a height when open of 48 inches (1219 mm) and a width of at least 32 inches (813 mm). The sill of the window or panel shall not be higher than 36 inches (914 mm) above the inside floor. Where not all of the windows are openable or breakable, the windows intended to satisfy the requirements of this section shall be readily identifiable.
Related Code Sections
903.2.11.2 Fire Protection Systems, Other Above-Grade Stories
An automatic sprinkler system shall be installed throughout every above-grade story of buildings below a height of 100 feet (30 480 mm), other than ...
NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.2 Other Above-Grade Stories
903.2.11.2 Fire Protection Systems, Other Above-Grade Stories
An automatic sprinkler system shall be installed throughout every above-grade story of buildings below a height of 100 feet (30 480 mm), other than ...
NYC Building Code 2022 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.2 Other Above-Grade Stories
8.5.2.1.3 General Requirements,
: When any portion of the escalator is more than six stories above grade, other values of C p may apply and should be determined based upon ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.5 Escalator and Moving Walk Safety Requirement for Seismic Risk Zone 2 or Greater > 8.5.2 Truss Members > 8.5.2.1 > 8.5.2.1.3
1909.4 Concrete, Design
22.8. Exception: For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction ...
Section 1909 Concrete, Structural Plain Concrete
, as modified by Section 1908 of this chapter.
Exception:
For Group R-3 occupancies and buildings of other occupancies less than two stories above grade ...