• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1903A.6 [OSHPD 1 & 4] Limits on Cementitious Materials

California Building Code 2016 (Vol 1 & 2) > 19A Concrete > 1903A Specifications for Tests and Materials > 1903A.6 [OSHPD 1 & 4] Limits on Cementitious Materials
JUMP TO FULL CODE CHAPTER
Modify ACI 318 Section 26.4.2.2(b) and Table 26.4.2.2(b) as follows:
The maximum percentage of pozzolans, including fly ash and silica fume, and slag cement in concrete assigned to all exposure categories shall be in accordance with Table 26.4.2.2(b) and Section 26.4.2.2(b) Items (1) and (2).
Where pozzolans are used as cementitous materials, duration for minimum specified compressive strength of concrete (f'c) that exceeds 28 days shall be considered an alternative system.

Related Code Sections


1903A.6 Concrete, [OSHPD 1 & 4] Limits on Cementitious Materials
, and slag cement in concrete assigned to all exposure categories shall be in accordance with Table 26.4.2.2(b) and Section 26.4.2.2(b) Items (1) and (2 ...
California Building Code 2016 (Vol 1 & 2) > 19A Concrete > 1903A Specifications for Tests and Materials > 1903A.6 [OSHPD 1 & 4] Limits on Cementitious Materials
1903A.6 Concrete, [OSHPD 1 & 4] Limits on Cementitious Materials
, and slag cement in concrete assigned to all exposure categories shall be in accordance with Table 26.4.2.2(b) and Section 26.4.2.2(b) Items (1) and (2 ...
California Building Code 2019 (Vol 1 & 2) > 19A Concrete > 1903A Specifications for Tests and Materials > 1903A.6 [OSHPD 1 & 4] Limits on Cementitious Materials
1903.6 Concrete, Limits on Cementitious Materials
26.4.2.2(b) Items (1) and (2). Where pozzolans are used as cementitious materials, duration for minimum specified compressive strength of concrete (f ...
California Building Code 2019 (Vol 1 & 2) > 19 Concrete > 1903 Specifications for Tests and Materials > 1903.6 Limits on Cementitious Materials
1910.2.1 Concrete, Cementitious Material
producer shall provide copies of the cementitious material supplier's certificate of compliance that represents the materials used by date of shipment ...
California Building Code 2019 (Vol 1 & 2) > 19 Concrete > 1910 Additional Requirements for Skilled Nursing Facilities, Intermediate Care Facilities, Acute Psychiatric and Non-Gac Buildings [OSHPD 1R, 2 & 5] > 1910.2 Tests and Materials > 1910.2.1 Cementitious Material
21.403.1 Referenced Standards, Cementitious Materials
Materials shall conform to the following applicable standards: Portland Cement—ASTM C 150 modified as follows: Limitation on insoluble residue ...
California Existing Building Code 2016 > Referenced Standards > 21-4 Hollow and Solid Load-Bearing Concrete Masonry Units > 21.403 — Materials > 21.403.1 Cementitious Materials
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING