2103.2.3.6 Organic Adhesives
JUMP TO FULL CODE CHAPTER
Water-resistant organic adhesives used for the installation of ceramic tile shall comply with ANSI A136.1. The shear bond strength after water immersion shall be not less than 40 psi (275 kPa) for Type I adhesive and not less than 20 psi (138 kPa) for Type II adhesive when tested in accordance with ANSI A136.1. Tile set in organic adhesives shall be installed in accordance with ANSI A108.4.
Related Code Sections
2103.2.3.6 Masonry, Organic Adhesives
Water-resistant organic adhesives used for the installation of ceramic tile shall comply with ANSI A136.1. The shear bond strength after water ...
Building Code 2021 of Illinois > 21 Masonry > 2103 Masonry Construction Materials > 2103.2 Mortar > 2103.2.3 Mortars for Ceramic Wall and Floor Tile > 2103.2.3.6 Organic Adhesives
2103.2.3.6 Masonry, Organic Adhesives
Water-resistant organic adhesives used for the installation of ceramic tile shall comply with ANSI A136.1. The shear bond strength after water ...
Building Code 2018 of Illinois > 21 Masonry > 2103 Masonry Construction Materials > 2103.2 Mortar > 2103.2.3 Mortars for Ceramic Wall and Floor Tile > 2103.2.3.6 Organic Adhesives
Section 2103 Masonry, Masonry Construction Materials
Water-resistant organic adhesives used for the installation ...
2508.4 Gypsum Board, Gypsum Panel Products and Plaster, Adhesives
Gypsum board and gypsum panel products secured to framing with adhesives in ceiling assemblies shall be attached using an approved fastening ...
Building Code 2021 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2508 Gypsum Construction > 2508.4 Adhesives
2508.4 Gypsum Board, Gypsum Panel Products and Plaster, Adhesives
Gypsum board and gypsum panel products secured to framing with adhesives in ceiling assemblies shall be attached using an approved fastening schedule ...
Building Code 2018 of Illinois > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2508 Gypsum Construction > 2508.4 Adhesives