§28-105.4.4 Ordinary Plumbing Work
JUMP TO FULL CODE CHAPTER
The following ordinary plumbing work may be performed without a permit, provided that the licensed plumber performing such work: (i) provides a monthly report listing completed work and work in progress during the preceding month, including the block, lot and address of each job, a description of the work performed or in progress at each address, and the location in each building where the work was performed or is in progress; (ii) pays the fees for such work in accordance with this code; and (iii) submits to the department a certification that the work was performed in accordance with this code and all applicable laws and rules. Ordinary plumbing work shall include:
- The removal of a domestic plumbing system not connected to a fire suppression or fire protection system, or the removal of a portion of such system.
- The relocation of up to two plumbing fixtures within the same room to a maximum of 10 feet (3048 mm) distant from the original location, except in health care facilities.
- The installation, replacement or repair of a food waste grinder (food waste disposal) or secondary back flow preventer and the replacement or repair of a sump pump.
- The replacement of closet bends.
- In buildings in occupancy group R-2 occupied by fewer than six families or in buildings in occupancy group R-3, the replacement of a gas water heater or a gas fired boiler with a capacity of 350,000 BTU or less where the existing appliance gas cock is not moved, provided that the plumber has inspected the chimney and found it to be in good operational condition.
- The repair or replacement of any non-gas, non-fire suppression piping not longer than 10 feet (3048 mm) inside a building, or connected piping previously repaired or replaced under this provision.
- The repair or replacement of non-fire suppression branch piping after the riser shutoff valve, including the replacement of fixtures, limited to two bathrooms and one kitchen per building per monthly reporting period.
- The replacement of flexible gas tubing no greater than 4 feet (1219 mm) in length located downstream of the existing gas cock to an appliance, provided such gas tubing does not penetrate a wall.
Related Code Sections
§28-105.4.4 Administration, Ordinary Plumbing Work
The following ordinary plumbing work may be performed without a permit, provided that the licensed plumber performing such work: (i) provides ...
NYC General Admin. Provisions 2014 > 1 Administration > 105 Permits > *§28-105.4 Work Exempt From Permit > §28-105.4.4 Ordinary Plumbing Work
§28-105.4.4 Administration, Ordinary Plumbing Work
The following ordinary plumbing work may be performed without a permit, provided that the licensed plumber performing such work: (i) provides ...
NYC General Admin. Provisions 2008 > 1 Administration > 105 Permits > §28-105.4 Work Exempt From Permit > §28-105.4.4 Ordinary Plumbing Work
107.4.1 Administration, New, Altered, Extended or Repaired Systems
ordinary plumbing work, the department may accept written certification from a licensed master plumber that the job was performed in compliance ...
NYC Plumbing Code 2014 > 1 Administration > 107 Inspections and Testing > 107.4 Testing > 107.4.1 New, Altered, Extended or Repaired Systems
107.3.1 Administration, New, Altered, Extended or Repaired Systems
for exhibition purposes. 3. For ordinary plumbing work, the department may accept written certification from a licensed master plumber ...
NYC Plumbing Code 2008 > 1 Administration > 107 Inspections and Testing > 107.3 Testing > 107.3.1 New, Altered, Extended or Repaired Systems
Section 107 Administration, Inspections and Testing
purposes. 3. For ordinary plumbing work, the department may accept written certification from a licensed master plumber that the job ...