23-143 Optional Regulations for Predominantly Built-Up Areas
JUMP TO FULL CODE CHAPTER
R4 R5
In the districts indicated without a letter suffix, the maximum floor area ratio and lot coverage and the minimum required open space for any zoning lot utilizing the special optional regulations of a predominantly built-up area are set forth in the following table:
District | Maximum Lot Coverage (in percent) | Minimum Required Open Space (in percent) | Maximum Floor Area Ratio |
R4 | 55 | 45 | 1.35 |
R5 | 55 | 45 | 1.65 |
Related Code Sections
1507.10 Roof Assemblies and Rooftop Structures, Built-Up Roofs
The installation of built-up roofs shall comply with the provisions of this section ...
NYC Building Code 2008 > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.10 Built-Up Roofs
1507.10 Roof Assemblies and Rooftop Structures, Built-Up Roofs
The installation of built-up roofs shall comply with the provisions of this section ...
NYC Building Code 2014 > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.10 Built-Up Roofs
1507.10 Roof Assemblies and Rooftop Structures, Built-Up Roofs
The installation of built-up roofs shall comply with the provisions of this section ...
NYC Building Code 2022 > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.10 Built-Up Roofs
1004.11.3.1 Dwelling Units and Sleeping Units, Option A
and bathing area such that travel between fixtures does not require travel through other parts of the unit, not more than one lavatory is required to comply ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1004 Type B Units > 1004.11 Toilet and Bathing Facilities > 1004.11.3 Toilet and Bathing Areas > 1004.11.3.1 Option A
17.2.1.2.4* Protection of Rack Storage of Plastic and Rubber Commodities,
protected. The density/ area criteria at the top of each option shall be applied to the ceiling sprinklers and the in-rack sprinklers shown in the option ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 17 Protection of Rack Storage of Plastic and Rubber Commodities > 17.2 Protection Criteria for Rack Storage of Group A Plastic Commodities Stored Up to and Including 25 ft (7.6 m) in Height > 17.2.1 Control Mode Density/Area Sprinkler Protection Criteria for Single-, Double-, and Multiple-Row Racks for Group A Plastic Commodities Stored Up to and Including 25 ft (7.6 m) in Height > 17.2.1.2 Ceiling Sprinkler Water Demand > 17.2.1.2.4*