1926.1427(e) Option (4): Licensing by a Government Entity
JUMP TO FULL CODE CHAPTER
For purposes of this section, a government licensing department/office that issues operator licenses for operating equipment covered by this standard is considered a government accredited crane operator testing organization if the criteria in paragraph (e)(2) of this section are met.
The requirements for obtaining the license include an assessment, by written and practical tests, of the operator applicant regarding, at a minimum, the knowledge and skills listed in paragraphs (j)(1) and (2) of this section.
The government authority that oversees the licensing department/office, has determined that the requirements in paragraphs (e)(2)(i) and (ii) of this section have been met.
The licensing department/office has testing procedures for re-licensing designed to ensure that the operator continues to meet the technical knowledge and skills requirements in paragraphs (j)(1) and (2) of this section.
The testing meets industry recognized criteria for written testing materials, practical examinations, test administration, grading, facilities/equipment and personnel.
A license issued by a government accredited crane operator testing organization that meets the requirements of this option:
Meets the operator qualification requirements of this section for operation of equipment only within the jurisdiction of the government entity.
Is valid for the period of time stipulated by the licensing department/office, but no longer than 5 years.
Related Code Sections
1926.1427(e) Cranes & Derricks in Construction, Option (4): Licensing by a Government Entity
A license issued by a government accredited crane operator testing organization that meets the requirements of this option ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1427 Operator Qualification and Certification > 1926.1427(e) Option (4): Licensing by a Government Entity
1926.1427(e)(2)(iii) Cranes & Derricks in Construction,
The government authority that oversees the licensing department/office, has determined that the requirements in paragraphs (e)(2)(i) and (ii ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1427 Operator Qualification and Certification > 1926.1427(e) Option (4): Licensing by a Government Entity > 1926.1427(e)(2) Licensing Criteria > 1926.1427(e)(2)(iii)
1926.1427(e)(2)(i) Cranes & Derricks in Construction,
The requirements for obtaining the license include an assessment, by written and practical tests, of the operator applicant regarding, at a minimum ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1427 Operator Qualification and Certification > 1926.1427(e) Option (4): Licensing by a Government Entity > 1926.1427(e)(2) Licensing Criteria > 1926.1427(e)(2)(i)
1926.1427(e)(2)(ii) Cranes & Derricks in Construction,
The testing meets industry recognized criteria for written testing materials, practical examinations, test administration, grading, facilities ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1427 Operator Qualification and Certification > 1926.1427(e) Option (4): Licensing by a Government Entity > 1926.1427(e)(2) Licensing Criteria > 1926.1427(e)(2)(ii)
1926.1427(e)(2)(iv) Cranes & Derricks in Construction,
The licensing department/office has testing procedures for re-licensing designed to ensure that the operator continues to meet the technical ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1427 Operator Qualification and Certification > 1926.1427(e) Option (4): Licensing by a Government Entity > 1926.1427(e)(2) Licensing Criteria > 1926.1427(e)(2)(iv)