1926.652(b)(4) Option (4)-Design by a Registered Professional Engineer
JUMP TO FULL CODE CHAPTER
Sloping and benching systems not utilizing Option (1) or Option (2) or Option (3) under paragraph (b) of this section shall be approved by a registered professional engineer.
At least one copy of the design shall be maintained at the jobsite while the slope is being constructed. After that time the design need not be at the jobsite, but a copy shall be made available to the Secretary upon request.
Designs shall be in written form and shall include at least the following:
The magnitude of the slopes that were determined to be safe for the particular project;
The configurations that were determined to be safe for the particular project; and
The identity of the registered professional engineer approving the design.
Related Code Sections
1926.652(c)(4) Excavations, Option (4)-Design by a Registered Professional Engineer
Support systems, shield systems, and other protective systems not utilizing Option 1, Option 2 or Option 3, above, shall be approved by a registered ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(4) Option (4)-Design by a Registered Professional Engineer
1926.652(b)(4)(ii)(A) Excavations,
The magnitude of the slopes that were determined to be safe for the particular project ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(b) Design of Sloping and Benching Systems > 1926.652(b)(4) Option (4)-Design by a Registered Professional Engineer > 1926.652(b)(4)(ii) > 1926.652(b)(4)(ii)(A)
1926.652(b)(4)(ii)(B) Excavations,
The configurations that were determined to be safe for the particular project ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(b) Design of Sloping and Benching Systems > 1926.652(b)(4) Option (4)-Design by a Registered Professional Engineer > 1926.652(b)(4)(ii) > 1926.652(b)(4)(ii)(B)
1926.652(c)(4)(i) Excavations,
Support systems, shield systems, and other protective systems not utilizing Option 1, Option 2 or Option 3, above, shall be approved by a registered ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(4) Option (4)-Design by a Registered Professional Engineer > 1926.652(c)(4)(i)
1926.652(c)(4)(ii)(B) Excavations,
The identity of the registered professional engineer approving the design ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(4) Option (4)-Design by a Registered Professional Engineer > 1926.652(c)(4)(ii) > 1926.652(c)(4)(ii)(B)