• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.652(c)(2) Option (2)-Designs Using Manufacturer's Tabulated Data

OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(2) Option (2)-Designs Using Manufacturer's Tabulated Data
JUMP TO FULL CODE CHAPTER

1926.652(c)(2)(i)

Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer.

1926.652(c)(2)(iii)

Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations shall be in written form at the jobsite during construction of the protective system. After that time this data may be stored off the jobsite, but a copy shall be made available to the Secretary upon request.

1926.652(c)(2)(ii)

Deviation from the specifications, recommendations, and limitations issued or made by the manufacturer shall only be allowed after the manufacturer issues specific written approval.

Related Code Sections


1926.652(c)(2) Excavations, Option (2)-Designs Using Manufacturer's Tabulated Data
Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(2) Option (2)-Designs Using Manufacturer's Tabulated Data
1926.652(c)(1) Excavations, Option (1)-Designs Using Appendices A, C and D
to this subpart. Designs for aluminum hydraulic shoring shall be in accordance with paragraph (c)(2) of this section, but if manufacturer's tabulated data ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(1) Option (1)-Designs Using Appendices A, C and D
1926.652(b)(3) Excavations, Option (3)-Designs Using Other Tabulated Data
Designs of sloping or benching systems shall be selected from and be in accordance with tabulated data, such as tables and charts ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(b) Design of Sloping and Benching Systems > 1926.652(b)(3) Option (3)-Designs Using Other Tabulated Data
1926.652(c)(3) Excavations, Option (3)-Designs Using Other Tabulated Data
Designs of support systems, shield systems, or other protective systems shall be selected from and be in accordance with tabulated data ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(3) Option (3)-Designs Using Other Tabulated Data
1926.652(b) Excavations, Design of Sloping and Benching Systems
and one-half horizontal to one vertical (34 degrees measured from the horizontal), unless the employer uses one of the other options listed below ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(b) Design of Sloping and Benching Systems
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING