• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-1005 Operators

NYC 1968 Code (Vol I) > 18 Elevators and Conveyors > 5 Equipment Operation > §27-1005 Operators
JUMP TO FULL CODE CHAPTER
Every power driven passenger elevator and freight elevator with a rise of more than one story, except automatic operation and continuous pressure elevators and sidewalk elevators, shall be in charge of a designated competent operator, who shall be at least eighteen years old, free from serious physical or mental defects, and selected with consideration of his or her abilities to perform his or her duties in a careful and competent manner, and who has been instructed in accordance with the requirements of the commissioner, except as otherwise specifically provided by law. Operators of amusement devices that require the services of a regular operator shall be at least eighteen years of age and shall have secured a certificate of competence from the commissioner. If the commissioner finds that any person engaged in running an elevator or amusement device is not competent to operate the elevator or device, the owner, agent or lessee of such elevator or amusement device shall, upon notice from the commissioner, discontinue the operation of such elevator or amusement device by such operator. Other devices listed in article one of this subchapter shall, when deemed necessary by the commissioner, be in charge of a designated competent operator conforming to such qualifications as the commissioner may prescribe except that operators for workers' hoists shall be assigned as required by the applicable provisions of reference standard RS 18-7.

Related Code Sections


1007.2 Boilers, Water Heaters and Pressure Vessels, Operation
The low-water cutoff shall automatically stop the combustion operation of the appliance when the water level drops below the lowest safe water level ...
NYC Mechanical Code 2008 > 10 Boilers, Water Heaters and Pressure Vessels > 1007 Boiler Low-Water Cutoff > 1007.2 Operation
1007.2 Boilers, Water Heaters and Pressure Vessels, Operation
The low-water cutoff shall automatically stop the combustion operation of the appliance when the water level drops below the lowest safe water level ...
NYC Mechanical Code 2014 > 10 Boilers, Water Heaters and Pressure Vessels > 1007 Boiler Low-Water Cutoff > 1007.2 Operation
1007.2 Boilers, Water Heaters and Pressure Vessels, Operation
Low-water cutoff controls and flow-sensing controls required by Section 1007.1 shall automatically stop the combustion operation of the appliance ...
NYC Mechanical Code 2022 > 10 Boilers, Water Heaters and Pressure Vessels > 1007 Boiler Low-Water Cutoff > 1007.2 Operation
1109.2 Refrigeration, Operation
Operating permits and qualification of operators for refrigeration systems shall comply with the requirements of the New York City Fire Code ...
NYC Mechanical Code 2008 > 11 Refrigeration > 1109 Periodic Testing > 1109.2 Operation
1109.2 Refrigeration, Operation
Operating permits and qualification of operators for refrigeration systems shall comply with the requirements of the New York City Fire Code ...
NYC Mechanical Code 2014 > 11 Refrigeration > 1109 Periodic Testing > 1109.2 Operation
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING