• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

606.1.3 Operator Logbook

NYC Fire Code 2014 > 6 Building Services and Systems > 606 Refrigerating Systems > 606.1 General > 606.1.3 Operator Logbook
JUMP TO FULL CODE CHAPTER
A logbook or other form of approved recordkeeping shall be maintained for all refrigerating systems whose operation requires either personal or general supervision by a certificate of qualification holder. For systems requiring personal supervision the logbook shall, at a minimum, contain an entry for each shift the system is in operation. For systems requiring general supervision the logbook shall, at a minimum, contain an entry for each day during which the system is in operation.

606.1.3.1 Logbook Entries

The logbook shall provide information relevant to the operation of the system, including any operating problems or deficiencies and required periodic tests. The signature of the certificate of qualification holder shall appear next to each entry.

Related Code Sections


1704.19.4 Structural Tests and Special Inspections, Records of Structural Safety Inspections in Construction Operations
The special inspection logbook shall be maintained at the special inspector's office and shall contain the following information: Project ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.19 Structural Safety During Construction Operations > 1704.19.4 Records of Structural Safety Inspections in Construction Operations
1704.20.9 Structural Tests and Special Inspections, Records of Special Inspections
The special inspection logbook shall be maintained at the special inspector's office and shall contain the following information: Project ...
NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > *1704.20 Structural Stability > 1704.20.9 Records of Special Inspections
1705.25.10 Special Inspections and Tests, Records of Special Inspections
The special inspection logbook shall be maintained at the special inspector's office and shall contain the following information: Project ...
NYC Building Code 2022 > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.25 Structural Stability > 1705.25.10 Records of Special Inspections
1007.2 Boilers, Water Heaters and Pressure Vessels, Operation
The low-water cutoff shall automatically stop the combustion operation of the appliance when the water level drops below the lowest safe water level ...
NYC Mechanical Code 2008 > 10 Boilers, Water Heaters and Pressure Vessels > 1007 Boiler Low-Water Cutoff > 1007.2 Operation
1007.2 Boilers, Water Heaters and Pressure Vessels, Operation
The low-water cutoff shall automatically stop the combustion operation of the appliance when the water level drops below the lowest safe water level ...
NYC Mechanical Code 2014 > 10 Boilers, Water Heaters and Pressure Vessels > 1007 Boiler Low-Water Cutoff > 1007.2 Operation
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING