• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5.1.8* Operations and Maintenance Manual

Fire Code 2018 of West Virginia > 5 Performance-Based Option > 5.1* General > 5.1.8* Operations and Maintenance Manual
JUMP TO FULL CODE CHAPTER
An approved Operations and Maintenance (O&M) Manual shall be provided by the owner to the AHJ and the fire department and shall be maintained at the facility in an approved location.

Related Code Sections


1302.13 Nonpotable Water Systems, Operation and Maintenance Manuals
1302.13.4. A detailed operations and maintenance manual ...
Plumbing Code 2015 of West Virginia > 13 Nonpotable Water Systems > 1302 On-Site Nonpotable Water Reuse Systems > 1302.13 Operation and Maintenance Manuals
1303.16 Nonpotable Water Systems, Operation and Maintenance Manuals
Operation and maintenance manuals shall be supplied with rainwater collection and conveyance systems in accordance with Sections 1303.16.1 through ...
Plumbing Code 2015 of West Virginia > 13 Nonpotable Water Systems > 1303 Nonpotable Rainwater Collection and Distribution Systems > 1303.16 Operation and Maintenance Manuals
5.1.8* Performance-Based Option, Operations and Maintenance Manual
An approved Operations and Maintenance (O&M) Manual shall be provided by the owner to the AHJ and the fire department and shall be maintained ...
Fire Code 2018 of West Virginia > 5 Performance-Based Option > 5.1* General > 5.1.8* Operations and Maintenance Manual
P2911.13 Water Supply and Distribution, Operation and Maintenance Manuals
Operation and maintenance materials shall be supplied with nonpotable on-site water reuse systems in accordance with Sections P2911.13.1 through ...
Residential Code 2015 of West Virginia > 29 Water Supply and Distribution > P2911 On-Site Nonpotable Water Reuse Systems > P2911.13 Operation and Maintenance Manuals
P2912.16 Water Supply and Distribution, Operation and Maintenance Manuals
Operation and maintenance manuals shall be supplied with rainwater collection and conveyance systems in accordance with Sections P2912.16.1 through ...
Residential Code 2015 of West Virginia > 29 Water Supply and Distribution > P2912 Nonpotable Rainwater Collection and Distribution Systems > P2912.16 Operation and Maintenance Manuals
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING