R612.4.2 Operation for Emergency Escape
JUMP TO FULL CODE CHAPTER
Window opening limiting devices shall be designed with release mechanisms to allow for emergency escape through the window opening without the need for keys, tools or special knowledge. Window opening limiting devices shall comply with all of the following:
- Release of the window opening-limiting device shall require no more than 15 pounds (66 N) of force.
- The window opening limiting device release mechanism shall operate properly in all types of weather.
- Window opening limiting devices shall have their release mechanisms clearly identified for proper use in an emergency.
- The window opening limiting device shall not reduce the minimum net clear opening area of the window unit below what is required by Section R310.1.1 of the code.
Related Code Sections
R612.4.2 Wall Construction, Operation for Emergency Escape
Window opening limiting devices shall be designed with release mechanisms to allow for emergency escape through the window opening without the need ...
Residential Code 2009 of Tennessee > 6 Wall Construction > R612 Exterior Windows and Doors > R612.4 Window Opening Limiting Devices > R612.4.2 Operation for Emergency Escape
23.8.6.2.3 Protected Premises Fire Alarm Systems,
The evacuation signal shall not be required to operate in exit stair enclosures and exit passageways ...
National Fire Alarm and Signaling Code 2016 of Tennessee > 23 Protected Premises Fire Alarm Systems > 23.8 System Requirements > 23.8.6 Fire Alarm System Notification Outputs > 23.8.6.2* Notification Appliances in Exit Stair Enclosures, Exit Passageways, and Elevator Cars > 23.8.6.2.3
1030.7 Means of Egress, Emergency Escape and Rescue Openings
, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles ...
Fire Code 2012 of Tennessee > 10 Means of Egress > 1030 Maintenance of the Means of Egress > 1030.7 Emergency Escape and Rescue Openings
2311.8.2 Motor Fuel-Dispensing Facilities and Repair Garages, Repair of Hydrogen Piping
percent hydrogen or less by volume. Defueling operations and exiting purge flow shall be vented in accordance with Section 2311.8.1.2 ...
Fire Code 2012 of Tennessee > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2311 Repair Garages > 2311.8 Defueling of Hydrogen From Motor Vehicle Fuel Storage Containers > 2311.8.2 Repair of Hydrogen Piping
R310.1 Building Planning, Emergency Escape and Rescue Required
Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening. Where basements contain ...
Residential Code 2009 of Tennessee > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.1 Emergency Escape and Rescue Required