• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 2205 Operation and Maintenance of Liquid Motor Fuel-Dispensing Facilities

NYC Fire Code 2014 > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2205 Operation and Maintenance of Liquid Motor Fuel-Dispensing Facilities
JUMP TO FULL CODE CHAPTER

2205.1 Tank Filling Operations for Liquid Motor Fuel

Delivery operations to tanks for liquid motor fuel shall comply with the requirements of FC 2205.1.1 through 2205.1.3 and the applicable requirements of FC Chapter 34.

2205.1.1 Delivery Vehicle Location

Where liquid delivery to a motor fuel storage tank is accomplished by positive-pressure operation, cargo tanks making delivery shall be positioned a minimum of 25 feet (7620 mm) from tanks receiving flammable liquids and 15 feet (4572 mm) from tanks receiving combustible liquids. During delivery, a cargo tank shall not obstruct a public street, private road, block motorists' view of roadways or impede the movement of vehicles or pedestrians.

2205.1.2 Tank Capacity Calculation

The driver, operator or attendant of a cargo tank shall, before making delivery to a tank, determine the unfilled, available capacity of such tank by an approved tank level-indicating device or method. A measuring stick shall not be used to measure the contents of the tank through the fill connection line, except where there is a direct fill connection.

2205.1.3 Tank Connections

Delivery of liquid motor fuel shall be made by means of approved liquid- and vapor-tight connections between the delivery hose and tank fill pipe. Where tanks are equipped with any type of vapor recovery system, all connections required for the safe and proper functioning of the particular vapor recovery process shall be made. Such connections shall be made liquid- and vapor-tight and remain connected throughout the delivery process. Vapors shall not be discharged at grade level during delivery.

2205.2 Equipment Maintenance

Liquid motor storage and dispensing systems shall be maintained in good working order at all times in accordance with FC 2205.2.1 through 2205.2.3.

2205.2.1 Dispensing Devices

Where maintenance to dispensing devices becomes necessary and such maintenance could allow the accidental release or ignition of liquid, the following precautions shall be taken:
  1. Only persons with a certificate of license and knowledgeable in performing the required maintenance shall perform the work.
  2. Electrical power to the dispensing device and pump serving the dispenser shall be shut off at the main electrical disconnect panel before maintenance begins.
  3. The emergency dispenser shutoff valve shall be closed before maintenance begins.
  4. Vehicular traffic and unauthorized persons shall be prevented from coming within 12 feet (3658 mm) of the dispensing device before and during maintenance.

2205.2.2 Dispenser Emergency Shutoff Valves

Dispenser emergency shutoff valves required by FC2206.7.4 shall be checked not less than once per year by manually tripping the hold-open linkage.

2205.2.3 Leak Detection System

The leak detection system required by FC2206.7.7 shall be inspected monthly for proper operation and tested at least annually in accordance with the manufacturer's specifications to ensure that it is in good working order.

2205.3 Use of Alcohol-Blended Motor Fuel in Existing Liquid Motor Fuel Storage and Dispensing Systems

Department approval shall be obtained prior to using a liquid motor fuel storage and dispensing system for alcohol-blended motor fuel when such system has previously been used to store and dispense another type of motor fuel. If approved, such system may be used alternatively for the various approved fuel types.

2205.4 Signage

Durable signs shall be conspicuously posted at motor fuel-dispensing facilities in accordance with this section.

2205.4.1 Tank Overfill Warning Sign

A warning sign shall be posted on or immediately adjacent to tank overfill alarm panel that reads: "CAUTION: WHEN ALARM ACTIVATES, TANK IS FILLED TO CAPACITY. DO NOT OVERFILL."

2205.5 Portable Fire Extinguishers

Approved portable fire extinguishers complying with the requirements of FC906 with a minimum rating of 40-B:C shall be provided and located such that an extinguisher is not less than 20 feet (6096 mm) but not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill connections.

Related Code Sections


406.5 Special Detailed Requirements Based on Use and Occupancy, Motor Fuel-Dispensing Facilities
Motor fuel-dispensing facilities shall be designed and constructed in accordance with the New York City Fire Code and Sections 406.5.1 through ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.5 Motor Fuel-Dispensing Facilities
406.7 Special Detailed Requirements Based on Use and Occupancy, Motor Fuel-Dispensing Facilities
Motor fuel-dispensing facilities shall be designed and constructed in accordance with the New York City Fire Code and Sections 406.7.1 through ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.7 Motor Fuel-Dispensing Facilities
406.5 Special Detailed Requirements Based on Use and Occupancy, Motor Fuel-Dispensing Facilities
Motor fuel-dispensing facilities shall be designed and constructed in accordance with the New York City Fire Code and this section ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor Vehicle-Related Occupancies > 406.5 Motor Fuel-Dispensing Facilities
§27-467 Special Uses and Occupancies, Motor Fuel Pumps
Motor fuel pumps and facilities may be provided within an open parking structure as an accessory use. Such facilities shall comply ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 11 Open Parking Structures > §27-467 Motor Fuel Pumps
Section 413 Gas Piping Installations, Compressed Natural Gas Motor Vehicle Fuel-Dispensing Stations
Motor fuel-dispensing facilities for CNG fuel shall be designed and operated in accordance with the New York City Fire Code ...
NYC Fuel Gas Code 2008 > 4 Gas Piping Installations > 413 Compressed Natural Gas Motor Vehicle Fuel-Dispensing Stations
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING