3320.7.2 Operation and Construction
JUMP TO FULL CODE CHAPTER
Power buggies shall be operated and constructed in accordance with the requirements of Sections 3320.7.2.1 through 3320.7.2.4.
Every power buggy shall be provided with brakes and tire surfaces capable of bringing it to a full stop within 25 feet (635 mm) on a level surface that is similar to the one on which it will be used and at full rated load and maximum design speed. Brakes shall be capable of being fixed in engagement to hold the full load stationary on a 25 percent grade.
All movement controls of every power buggy shall be so arranged or shielded that they cannot be inadvertently engaged or the buggy accidentally set in motion.
No power buggy shall be left unattended on any grade sufficiently steep to cause it to coast if free of engine and brake resistance.
Power buggies shall not be used on ramps, runways, or platforms that do not meet the requirements of Section 3315
Related Code Sections
3320.7.2 Safeguards During Construction or Demolition, Operation and Construction
Power buggies shall be operated and constructed in accordance with the requirements of Sections 3320.7.2.1 through 3320.7.2.4 ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3320 Material Handling Equipment > 3320.7 Power Buggies > 3320.7.2 Operation and Construction
3320.7.2 Safeguards During Construction or Demolition, Operation and Construction
Power buggies shall be operated and constructed in accordance with the requirements of Section 3320.7.2.1 through 3320.7.2.4 ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3320 Material Handling Equipment > 3320.7 Power Buggies > 3320.7.2 Operation and Construction
3320.7.2 Safeguards During Construction or Demolition, Operation and Construction
Power buggies shall be operated and constructed in accordance with the requirements of Sections 3320.7.2.1 through 3320.7.2.4 ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3320 Additional Requirements for Certain Material Handling Equipment > 3320.7 Power Buggies > 3320.7.2 Operation and Construction
3304.3.3 Safeguards During Construction or Demolition, Underground Construction Operations
Whenever excavation or drilling, for any purpose, to a depth greater than 100 feet (30 480 mm) is proposed in a block that has any part of its ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3304 Excavation > 3304.3 Notification > 3304.3.3 Underground Construction Operations
3320.7.2.3 Safeguards During Construction or Demolition, Parking on Grades
No power buggy shall be left unattended on any grade sufficiently steep to cause it to coast if free of engine and brake resistance ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3320 Material Handling Equipment > 3320.7 Power Buggies > 3320.7.2 Operation and Construction > 3320.7.2.3 Parking on Grades