• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2308.5.5.2 Openings in Interior Bearing Partitions

Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.5 Openings in Walls and Partitions > 2308.5.5.2 Openings in Interior Bearing Partitions
JUMP TO FULL CODE CHAPTER
Headers shall be provided over each opening in interior bearing partitions as required in Section 2308.5.5.1. The spans in Table 2308.4.1.1(2) are permitted to be used. Wall studs shall support the ends of the header in accordance with Table 2308.4.1.1(1) or 2308.4.1.1(2), as applicable.

Related Code Sections


2308.5.5.2 Wood, Openings in Interior Bearing Partitions
Headers shall be provided over each opening in interior bearing partitions as required in Section 2308.5.5.1. The spans in Table 2308.4.1.1(2 ...
Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.5 Openings in Walls and Partitions > 2308.5.5.2 Openings in Interior Bearing Partitions
2308.5.5.2 Wood, Openings in Interior Bearing Partitions
Headers shall be provided over each opening in interior bearing partitions as required in Section 2308.5.5.1. The spans in Table 2308.4.1.1(2 ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.5 Openings in Walls and Partitions > 2308.5.5.2 Openings in Interior Bearing Partitions
2308.5.5.3 Wood, Openings in Interior Nonbearing Partitions
Openings in nonbearing partitions are permitted to be framed with single studs and headers. Each end of a lintel or header shall have a bearing ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.5 Openings in Walls and Partitions > 2308.5.5.3 Openings in Interior Nonbearing Partitions
2308.5.4 Wood, Nonload-Bearing Walls and Partitions
) on center. In interior nonload-bearing walls and partitions, studs are permitted to be set with the long dimension parallel to the wall. Where studs ...
Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.4 Nonload-Bearing Walls and Partitions
2308.5.4 Wood, Nonload-Bearing Walls and Partitions
In interior nonload-bearing walls and partitions, studs are permitted to be set with the long dimension parallel to the wall. Where studs are set ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.4 Nonload-Bearing Walls and Partitions
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING